background image

01089820R01 

© Follett Corporation 6/15

801 Church Lane • Easton, PA 18040, USA

Toll free (877) 612-5086 • +1 (610) 252-7301

www.follettice.com

Follett is a registered trademark of Follett Corporation, registered in US.

Содержание Symphony 01089580

Страница 1: ...ine system is required to ensure peak performance and delivery of clean sanitary ice Immediately perform Cleaning Sanitizing procedure according to instructions shipped with dispenser when this Pressu...

Страница 2: ...quipment Wear rubber gloves and safety goggles or face shield when handling cleaner or sanitizer mixtures Use only Follett approved cleaners It is a violation of Federal law to use Sanitizing solution...

Страница 3: ...Mix a 200 ppm active quaternary sanitizing solution of 1 gal 3 8 L 100 F 38 C water and 1 6 oz 47 ml Nu Calgon IMS II Sanitizer P N 00979674 7 Fill pre filter bowl to just below the o ring with saniti...

Страница 4: ...cups 13 Remove any panels required to gain access to water reservoir evaporator drain tube and compressor switch Note Consult the Operation and Service manual shipped with your unit 14 Locate the Comp...

Страница 5: ...2 3 21 Turn ON water supply 22 Plug in dispenser and dispense water into a container for 30 seconds Fig 8 to flush sanitizer from the dispenser water lines 23 Discard water collected in container 24 D...

Страница 6: ...089820R01 Follett Corporation 6 15 801 Church Lane Easton PA 18040 USA Toll free 877 612 5086 1 610 252 7301 www follettice com Follett is a registered trademark of Follett Corporation registered in U...

Страница 7: ...089820R01 Follett Corporation 6 15 801 Church Lane Easton PA 18040 USA Toll free 877 612 5086 1 610 252 7301 www follettice com Follett is a registered trademark of Follett Corporation registered in U...

Страница 8: ...lug in dispenser and dispense water into a container for 30 seconds Fig 8 to flush sanitizer from the dispenser water lines 25 Discard water collected in container 26 Press the CLEAN switch to purge s...

Страница 9: ...5 3 cups 13 Remove the front cover and set aside 14 Locate the ice machine electrical box Fig 6 1 and press CLEAN switch Fig 6 2 The MAINTENANCE light will turn on and the machine will drain 15 Wait...

Страница 10: ...a 200 ppm active quaternary sanitizing solution of 1 gal 3 8 L 100 F 38 C water and 1 6 oz 47 ml Nu Calgon IMS II Sanitizer P N 00979674 7 Fill pre filter bowl to just below the o ring with sanitizin...

Страница 11: ...pment Wear rubber gloves and safety goggles or face shield when handling cleaner or sanitizer mixtures Use only Follett approved cleaners It is a violation of Federal law to use Sanitizing solution in...

Страница 12: ...ine system is required to ensure peak performance and delivery of clean sanitary ice Immediately perform Cleaning Sanitizing procedure according to instructions shipped with dispenser when this Pressu...