Installing remote icemaker
(automatic load units only)
1. Position icemaker in desired location.
2. Push one end of ice transport tube(s) through hole(s) provided in side of dispenser.
3. Route tube into ice tube bracket inside dispenser and engage bracket tabs in holes located in end of ice
transport tube(s). (See drawings below.)
4. Proceed with ice transport tube installation from dispenser to icemaker in compliance with instructions
contained in icemaker installation manual packed with icemaker.
7
Correct installation of remote icemaker(s) is critical to proper performance of
icemaker and dispenser.
Check to make sure bin signal on icemaker control board is switched to 24 volt
connection.
Refer to installation manual packed with icemaker for important details on ice
transport tube run, ventilation requirements and other installation requirements.
Failure to comply with instructions will void warranty.
!
Tabs in ice tube
retainer bracket
engage holes in ice
tube and hold tube
in place
25mm
ice tube
Side view
ice tube
Ice tube retainer bracket
thermostat
Front view
thermostat