Vision • RIDE Technology
Maestro Plus
11
5.
External Connections
5.1
Air-cooled ice machines only
5.2
Water-cooled ice machines only
CONDENSER
OUTLET
Front View - Water Cooled
Front View - Air Cooled
➌
➋
➍
➊
➋
➊
CONDENSER
OUTLET
Front View - Water Cooled
Front View - Air Cooled
➌
➋
➍
➊
➋
➊
§
Install drain line
➊
(3/4" MPT).
The rigid drain line from the ice machine must have
at least 1/4" per foot (6,4 mm/0,3 m) pitch.
§
Install ice machine potable water supply
➋
(3/8" FPT)
.
Note: Follett recommends a Follett water filter
system be installed in the ice machine inlet
water line (standard capacity #00130299, high
capacity #00978957, carbonless high capacity
#01050442).
§
Install drain line
➊
(3/4" MPT).
The rigid drain line from the ice machine must
have at least 1/" per foot (6,4 mm/0,3 m) pitch.
§
Install ice machine potable water supply
➋
(3/8" FPT).
Note: Follett recommends a Follett water filter
system be installed in the ice machine inlet
water line (standard capacity #00130299,
high capacity #00978957, carbonless high
capacity #01050442).
§
Connect cooling water supply
➌
and return
➍
(3/8" FPT).
5.3
Bin Stat Cable
ICE MACHINE
➊
➋
Note: Do not apply
power to ice
machine bin signal
connection! Ice
machine can only
see contact closure.
IN from
dispenser
OUT to
ice machine
RELAY
§
Route 2-pin bin stat cable from Vision dispenser
➊
and connect at front of ice machine
➋
.