10
Maestro 400 Series Top Kit for Lancer
Fig. 7
13. Remove ice machine top panel and louvered side
panel.
14. Insert ice transport tube to a 1/2" (13mm) depth
through mounting bracket (Fig. 7 and 8.1) and
secure transport tube away from condenser fan
under fl oat reservoir bracket
(Fig. 8.2).
15. Tighten clamp screw on ice machine base securely
(Fig. 8.3).
16. Uncoil capillary tube from bin thermostat and route
through hole in gasket to mounting bracket and
secure as shown (Fig. 7).
17. Reinstall ice machine louvered side panel and top
panel.
GO TO STARTUP – STEP 27.
ice transport tube
bin thermostat
1/2"
2"
Fig. 8
2
1
3
tighten
clamp
scre
w
insert ice
transport
t
ub
e