6
Dimensions and clearances
Entire front of icemaker must be clear of obstructions/connections to allow removal.
1" (26mm) clearance above icemaker for service.
1" (26mm) minimum clearance on sides.
Condensing Unit
Front View
Condensing Unit
Side View
Condensing Unit
Back View
40.7"
(1034mm)
31.25"
(794mm)
5/8" OD low pressure line (suction line)
Power connections
3/8" OD high pressure line (liquid line)
26.54"
(675mm)
Front View
Side View
Back View
3/8" OD push-in
water inlet
5/8" suction line
3/8" liquid line
Ice transport tube connection
19.3" (491mm)
2.5" (64mm)
15.69" (399mm)
2.53"
(65mm)
6.95"
(177mm)
14.47"
(368mm)
2.87
(73mm)
1.81
(46mm)
3/4" MPT drain
PSIG
THE USA
MADE IN
OZ
PHASE
SINGLE
LOW SIDE
CHARGE
PART NO
R
R
HZ
Easton Pennsylvania
208264
AMPS
AMPS
VOLTS
SERIAL NO
CORPORATION
MODEL
Service No.
Product
Module No.
REFRIGERANT
FULL LOAD AMPS
Stock Module Identification Plate
DESIGN PRESSURE HIGH SIDE
MAX. BRANCH CIRCUIT FUSE SIZE
MIN. BRANCH CIRCUIT AMPACITY
MOTOR COMPRESSOR THERMALLY PROTECTED
C
NSF
U L
U L
21.05" (535mm)
23.50"
(597mm)
21.28" (541mm)
Air exhaust
both sides
23.77" (604mm)
G
L2
L1
NEMA 5-15
right angle