7
HARMONY • SATELLITE-FILL
self-contained
ON
OFF
Cornelius models ED, DB, DF, IDC and
FLAVOR FUSION
Adjust the agitation timer located on the
Cornelius PC board to 1 second on, 1 hour
off.
Note:
See Cornelius manual for more
information.
Agitation adjust. – CORNELIUS
3.5
PRESS IN ON
THIS SIDE TO
TURN SWITCH
ON.
SWITCH
ON
SWITCH
OFF
PRESS IN ON
THIS SIDE TO
TURN SWITCH
OFF.
ROCKER
SWITCHES
(VIEW LOOKING
DOWN)
SIDE VIEW
SIDE VIEW
1
2
3
4
5
6
7
8
OFF
SWITCH
NUMBER
AGITATION FREQUENCY
NO A
GIT
ATION
10 MINUTES
20 MINUTES
30 MINUTES
40 MINUTES
50 MINUTES
60 MINUTES
70 MINUTES
80 MINUTES
90 MINUTES
100 MINUTES
110 MINUTES
120 MINUTES
130 MINUTES
140 MINUTES
150 MINUTES
5
6
7
8
O
O
O
O
O
O
O
X
O
O
X
O
O
O
X
X
O
X
O
O
O
X
O
X
O
X
X
O
O
X
X
X
X
O
O
O
X
O
O
X
X
O
X
O
X
O
X
X
X
X
O
O
X
X
O
X
X
X
X
O
X
X
X
X
SWITCH
NUMBER
AGITATION TIME
1 SECOND
2 SECONDS
3 SECONDS
4 SECONDS
3
4
O
O
O
X
X
O
X
X
X = ON
O = OFF
Lancer 4500 series only
Adjust the agitation time to 1 second, and the agitation frequency to 150 minutes. See Lancer
manual for more information.
Agitation adjustments – LANCER 4500 SERIES
3.6