Follett D5A Скачать руководство пользователя страница 11

Table 1 – Refrigeration pressure data*  

Ambient

50°F

55°F

60°F

65°F

70°F

75°F

80°F

85°F

90°F

95°F

100°F

110°F

air temp.

10°C

12.7°C

15.6°C

18.3°C

21.1°C

23.9°C

26.7°C

29.4°C

32.2°C

35°C

37.8°C

43.3°C

Water temp.

50°F

55°F

60°F

65°F

70°F

75°F

80°F

85°F

90°F

95°F

100°F

105°F

at float

10°C

12.7°C

15.6°C

18.3°C

21.1°C

23.9°C

26.7°C

29.4°C

32.2°C

35°C

37.8°C

40.6°C

Air-cooled

Suction pressure
PSIG

30

31

32

33

34

35

35

36

37

38

39

41

Discharge pressure 
PSIG

155

167

178

192

200

210

223

238

250

269

288

310

Water-cooled

Suction pressure 

PSIG 32

32

33

33

34

35

35

35

36

37

39

40

Discharge pressure
PSIG

185

185

185

185

185

185

185

185

185

185

212

229

* Notes:

1)  Water regulating valve is factory set at 185 PSIG head pressure.
2)  Readings within 10% of above table values should be considered normal.

Table 2 – Compressor data

Compressor current draw

Air-cooled

Ambient air temp.

60°F/15.6°C

70°F/21.1°C

80°F/26.7°C

90°F/32.2°C

100°F/37.8°C

6.3A

6.5A

6.7A

6.9A

7.1A

Water-cooled

Water temp. at float

50°F/10°C

60°F/15.6°C

70°F/21.1°C

80°F/26.7°C

90°F/32.2°C

6.6A

6.7A

6.7A

6.8A

6.9A

Locked rotor amps

48.0

Water-cooled icemaker capacity/24 hours

Table 3 – Gearmotor data

Gearmotor current

2.25A (nominal)

Locked rotor amps

14 amps

10

Inlet  Water Temperature °F/°C

Ambient Air Temperature °F/°C

Inlet  Water Temperature °F/°C

50

°

475

470

465

460

450

lbs.

F

°

60

°

70

°

80

°

90

°

100

°

C

°

16

°

21

°

27

°

32

°

38

°

10

°

215

213

211

209

204

kg.

60

°

445

435

430

420

415

lbs.

16

°

202

197

195

191

188

kg.

70

°

415

410

400

390

380

lbs.

21

°

188

186

181

177

172

kg.

80

°

390

380

370

360

350

lbs.

27

°

177

172

168

163

159

kg.

90

°

370

360

350

340

325

lbs.

32

°

168

163

159

154

147

kg.

Ambient Air Temperature °F/°C

50

°

570

515

465

410

360

lbs.

F

°

60

°

70

°

80

°

90

°

100

°

C

°

16

°

21

°

27

°

32

°

38

°

10

°

259

234

211

186

163

kg.

60

°

535

495

450

405

340

lbs.

16

°

243

225

204

184

154

kg.

70

°

480

440

400

360

320

lbs.

21

°

218

200

181

163

145

kg.

80

°

465

425

390

350

315

lbs.

27

°

211

193

177

159

143

kg.

90

°

420

385

350

310

275

lbs.

32

°

191

175

159

141

125

kg.

Air-cooled icemaker capacity/24 hours

Содержание D5A

Страница 1: ...654R01 UL R5A icemaker with countertop dispenser T5A W icemaker mounted on ice storage bin R5A icemakers with undercounter dispenser 801 Church Lane PO Box D Easton PA 18044 Toll free 800 523 9361 888...

Страница 2: ...ator information Cleaning procedures Recommended monthly cleaning of condenser air cooled icemaker only 1 Use vacuum cleaner or stiff brush to carefully clean condenser coils of air cooled icemaker to...

Страница 3: ...from ice storage area and allow ice made during the sanitizing process to fall into ice bin area Note If bin will not be cleaned at this time place a large pan in bin storage area to catch ice or conn...

Страница 4: ...ce the icemaker Operational and diagnostic sequences The wiring diagrams which follow illustrate the circuitry of Follett icemakers used with ice dispensers Both normal operation of the icemaker stage...

Страница 5: ...in by the initial high current draw of the compressor The B E and WTR LED remain on M GRD L1 L1 L2 L2 L2 L2 L2 COMPRESSOR FAN DRIVE DR C 20M 60M 2ND WTR B T B E RESET X GRD G B W FAN BLACK WHITE BLACK...

Страница 6: ...ntinues to run for 60 seconds The purpose of this function is to drive the remaining ice out of the evaporator and to boil off any refrigerant remaining in the evaporator M GRD L1 L1 L2 L2 L2 L2 L2 CO...

Страница 7: ...AN DRIVE DR C 20M 60M 2ND WTR B T B E RESET X GRD G B W FAN BLACK WHITE BLACK BLACK R ORANGE S S L COMPRESSOR C RED BLACK BLACK WHITE INPUT POWER CONTROL BOARD BLACK GEARMOTOR 24V COMMON LINE VAC RED...

Страница 8: ...dition If the icemaker runs without problems for 60 minutes and no additional torque errors occur the 60M LED will go off M GRD L1 L1 L2 L2 L2 L2 L2 COMPRESSOR FAN DRIVE DR C 20M 60M 2ND WTR B T B E R...

Страница 9: ...L1 L2 WATER SENSOR PWR 8 Diagnostic sequence Stage 10 If the water level in the float reservoir drops to an unacceptable level the WTR LED will go out shutting the icemaker off Also the BT LED will c...

Страница 10: ...GRD G B W FAN BLACK WHITE BLACK BLACK R ORANGE S S L COMPRESSOR C RED BLACK BLACK WHITE INPUT POWER CONTROL BOARD BLACK GEARMOTOR 24V COMMON LINE VAC RED RED COMPRESSOR SWITCH WHITE BLACK BIN T STAT W...

Страница 11: ...1 C 80 F 26 7 C 90 F 32 2 C 100 F 37 8 C 6 3A 6 5A 6 7A 6 9A 7 1A Water cooled Water temp at float 50 F 10 C 60 F 15 6 C 70 F 21 1 C 80 F 26 7 C 90 F 32 2 C 6 6A 6 7A 6 7A 6 8A 6 9A Locked rotor amps...

Страница 12: ...his period the system should not rise above 1000 microns If the system rises above 1000 microns evacuate the system again If the system rises above 1000 microns for a second time check the system for...

Страница 13: ...ting base 4 Fill gearmotor shaft well with food grade grease 5 Install condensate shield and seat against gearmotor boss 6 Install bearing O ring in groove in evaporator mounting base 7 Lower bottom b...

Страница 14: ...efficient compressor Corrective action 1 Check that unit is plugged in circuit breakers are on 2 Adjust or replace ice level control 3 Check reservoir for water restore water to unit 4 See Problem 6 b...

Страница 15: ...dirty condenser coil 2 Compressor not pumping 3 Low refrigerant charge 1 Compressor switch in OFF position 2 No output on compressor and fan motor terminals on control board 1 Replace O ring 1 Elimin...

Страница 16: ...Air cooled icemaker right side Air cooled icemaker left side 15 1 2 3 4 5 6 7 11 10 12 8 9 12 6 5 16 17 15 14 13 2 18...

Страница 17: ...3 Tubing plastic 5 8 ID x 13 16 OD sold by foot 9 501190 Mounting bracket gearbox 10 501992 Gearbox motor assembly 115V 60Hz 11 501993 Gearbox motor assembly 230V 50Hz 11 501191 Tubing plastic food gr...

Страница 18: ...Water cooled icemaker right side Water cooled icemaker left side 17 1 3 4 5 6 7 8 12 11 9 13 10 13 2 14 18 16 15 17 19 20...

Страница 19: ...rmal 8 501289 Drain pan evaporator 9 500623 Tubing plastic 5 8 ID x 13 16 OD sold by foot 10 501992 Gearbox motor assembly 115V 60Hz 11 501993 Gearbox motor assembly 230V 50Hz 11 501190 Mounting brack...

Страница 20: ...e Not shown 501992 Gearbox motor assembly 13 501993 Gearbox motor assbly 230V 13 501190 Mounting base gearbox Not shown 502220 Compression nozzle with double drain below 502221 Compression nozzle with...

Страница 21: ...97 Bearing needle 2 required 17 500781 2 Gear 3 pinion assembly 18 500798 Shaft 2 gear 19 500878 4 Gear 5 pinion assembly 20 501989 Gearcase 21 501994 Vent plug 23 501991 Bearing ball sealed 24 501144...

Страница 22: ...50Hz 2 502331 Board control circuit 115V 60Hz 3 502349 Board control circuit 230V 50Hz 3 502116 Water sensor 4 500006 Switch on off compressor 5 500514 Bin thermostat T5A W icemakers only Not shown 50...

Страница 23: ...transport tube insulation 501176 Ice tube insulation sold by the foot Ice tube end kit Required length of transport tube 500366 must be ordered Tube insulation 501176 must also be ordered for all rem...

Страница 24: ...Enamel All U150 series with air cooled icemakers R5A None Enamel All U150 series with water cooled icemakers R5W None Enamel All U300 series with air cooled icemakers R5A None Enamel All U300 series...