Diagnostic sequence – Stage 10
If the water level in the fl oat reservoir drops to an unacceptable level, the WTR LED goes out, shutting the ice machine
off. Also, the BT LED comes on, preventing the ice machine from restarting for twenty minutes. If water is restored, the
WTR LED comes back on and fl ashes to alert the technician that water to ice machine has been lost. The ice machine
restarts at the end of the 20 minute time delay. The fl ashing WTR LED can be cleared by pressing the reset button.