RIDE™ remote ice delivery ice machine installation procedure
Install ice machine and rough-in utilities without optional slide-out accessory
The requirements below are for ice machine installation without the Follett slide-out accessory. These procedures
ensure that the ice machine can be easily removed as one unit for cleaning and maintenance. For installation with the
slide-out accessory, refer to instructions to install ice machine and rough-in utilities with optional slide-out accessory.
General requirements
Front of ice machine free of obstructions, plumbing lines, electric conduits.
305mm (12") minimum clearance above ice machine for access to ice machine components.
153mm (6") minimum clearance between exhaust side of ice machine and adjacent equipment.
Do NOT
weld ice machine to counter channels.
Large, removable panels in counter face to allow ice machine removal.
Machine stand accessory required for ice machines not supported on counter channels.
Connection requirements
Compression fi ttings for water and drain lines.
Separate drains for condenser and ice machine. Do NOT connect drains.
Power supply with 6 feet (2m).
front of
ice machine
clear
305mm (12")
clearance
separate power
to dispenser
separate power
to ice machine
compression fittings for
water and drain lines
water shut off
bin signal from dispenser
to ice machine