17
Compressor data
Compressor current draw
Air-cooled
Ambient air temp.
60 F/16 C
70 F/21 C
80 F/27 C
90 F/32 C
100 F/38 C
8.01A
8.26A
8.77A
9.06A
9.36A
Water-cooled
Condenser water temp
50 F/10 C
60 F/16 C
70 F/21 C
80 F/27 C
90 F/32 C
9.09A
9.14A
9.06A
9.15A
9.39A
Locked rotor amps
96.8
Gearmotor data
Brother
Gearmotor current
2.8A (nominal)
Locked rotor amps
15 amps
Resistance of windings
208-230 vac gearmotor (Brother)
6.2
Ω
Compressor start winding
3.5
Ω
Compressor run winding
0.7
Ω
Fan motor
38
Ω