![Follett C25R5A/W Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/follett/c25r5a-w/c25r5a-w_installation-manual_2314925009.webp)
Installing remote icemaker
(Models C25R5A/W, C50R5A/W, H25R5A/W, H50R5A/W)
When 10 feet (3 m) or less of ice transport tube is required to carry ice from evaporator port to dispenser, the unit will be
shipped with one end of tube already installed in mounting bracket of dispenser. For runs that exceed 10 feet (3 m) the
tubing is not mounted and requires a different installation procedure. Refer to appropriate section below for your specific
installation.
Units shipped with standard 10 feet (3 m) of ice transport tube
1. Position icemaker in desired location.
2. Refer to R5A/W Installation Manual (Form #206428) packed with icemaker for installation instructions, restrictions on
ice transport tube run and ventilation requirements for remote icemakers.
Units shipped with more than 10 feet (3 m) of ice transport tube
1. Remove top and rear access panel from dispenser.
2. Run end of ice transport tube with 3/16" (1.9 mm) hole through right hand knockout in back of dispenser or through
counter into bottom of dispenser, being careful to avoid any
bends with less than a 6" (15.2 cm) radius.
3. Insert tube in internal chase in rear inside corner of dispenser
(right side as you face rear of dispenser) and push up into
storage area.
4. Push 3/16" (5 mm) hole near end of tube into engaging pin on
ice tube bracket (see drawing at right).
5. Install supplied insulation to run of transport tube required for
your site, leaving approximately 2" (5.1 cm) of tube exposed
at free end.
6. Check that insulated tube runs continuously uphill to
dispenser with no dips.
7
20.625"
524 mm
16"
406 mm
1.0625"
27 mm
2.3125"
59 mm
3.40625" (87 mm)
11.4375"
291 mm
4.59375"
125 mm
utility cutout
3.5"
89 mm
1.28125"
33 mm
25.625"
651 mm
9.5"
241 mm
44.25"
1124 mm
Wall Bracket
support angle
3/8" (10 mm)
fasteners (6 sites)
wall stud
filler strip
9.5"
241 mm
20.625"
524 mm
16"
406 mm
1.0625"
27 mm
2.3125"
59 mm
3.40625" (87 mm)
11.4375"
291 mm
4.59375"
125 mm
utility cutout
3.5"
89 mm
1.28125"
33 mm
29.625"
752 mm
11.5"
292 mm
48.25"
1226 mm
Wall Bracket
support angle
3/8" (10 mm)
fasteners (6 sites)
wall stud
filler strip
11.5"
292 mm
H50T5A/W mounting dimensions
H25T5A/W mounting dimensions
1"
2.5 cm
Capillary
tube
Ice
tube
Engaging pin
Ice tube
bracket
Back wall
3/16"
1.9 mm
hole in
ice tube
See R5A/W Installation Manual (Form #206428) for critical installation instructions for
remote icemakers. Failure to comply with these instructions will result in poor
performance and void warranty.
!