Installing countertop dispensers without legs
1. For units where utilities will exit through back of dispenser, remove cap from drain fitting on back of unit and install
cap on fitting tee inside dispenser.
2. Position dispenser in desired
location, mark dispenser outline on
counter, and remove dispenser.
3. Regardless of how utilities will be
connected, drill four (4) holes in
counter to anchor dispenser to
counter (see figures above).
4. For units with utilities exiting
through counter, make appropriate
counter cut-out as shown above.
5. Apply a thick bead - approximately
1/4" (6 mm) diameter - of NSF
listed silicone sealant (Dow-
Corning RTV-732 or equivalent)
1/4" (6 mm) inside marked outline
of dispenser.
6. Carefully lower dispenser on counter in
proper position and secure to counter with four (4) bolts.
7. Smooth excess sealant around outside of dispenser.
8. If dispenser has remote icemaker and unit is equipped with water station accessory, make water connection for water
station inside dispenser as indicated.
9. Make final connections. Proceed with instructions for installing remote or integral icemakers as appropriate.
23.0625"
586 mm
. 375"
10 mm
10.5"
267 mm
.5" (13 mm) to
cutout
16.75"
425 mm
21"
533 mm
2.125"
54 mm
.375"
diameter -
4 places
9" x 14"
229 mm x 356 mm
cutout
1.5626"
40 mm
10.5"
267 mm
.5" (13 mm) to
cutout
.375"
diameter -
4 places
9" x 14"
229 mm x 356 mm
cutout
20.125"
(511 mm)
21" (533 mm)
12.5"
318 mm
19"
483 mm
6" min.
152 mm
2.5"
(64 mm)
Counter cut-out for units with drain pan
Counter cut-out for units without drain pan
electrical
connection
6.125"
15.6 cm
5.156"
13.1 cm
10.5"
26.7 cm
14.75"
37.5 cm
3/4"
FPT drain
plumbing
connection
access
panel
junction box
Rear connections – Countertop
models with integral icemakers
electrical
connections
6.125"
15.6 cm
5.156"
13.1 cm
ice transport
tube
10.5"
26.7 cm
14.75"
37.5 cm
3/4"
1.9 cm
FPT drain
plumbing
connection
access
panel
junction box
Rear connections – Countertop
models with remote icemakers
4
Counter cut-outs
Note: Electrical connection box can also be accessed through front of dispenser by removing front cover, black plastic
chute cover and stainless splash panel.
Shaded
areas
indicate
internal
connections