Follett Advantage REFADV5-SD Скачать руководство пользователя страница 6

Cleaning

Weekly

Interior:  Using a sponge or soft cloth, clean unit with a non-abrasive, non-chlorinated, all-purpose detergent.
Exterior: Wipe exterior with a soft cloth.

Semi-Annual Cleaning

Cleaning of the condenser at the rear of the unit is recommended at least twice a year. In the case of use in 
particularly dusty environments, this should be done more frequently (every 3 months).
This should be done by facility staff: cleaning can be done using soft bristle brushes and vacuum cleaners, or 
compressed air, taking care not to bend the condenser’s fins. Protective gloves, a dust mask, and protective 
goggles should be worn.

1.  Disconnect power to unit.
2.  Remove rear panel.
3.  Remove drain pan. 
4.  Clean drain pan with a non-abrasive, non-chlorinated all-purpose detergent.
5.  Reinstall drain pan.
6.  Use a vacuum cleaner with brush attachment to clean condenser and compressor motor and related 

parts.

7.  Reinstall rear panel.

Defrosting

The evaporator is self-defrosting. If a layer of ice/frost does form, power off the unit and leave the door slightly 
open, and allow refrigerator to defrost naturally. 

Note: DO NOT use objects to manually chip the ice.

Circuit Diagram

C1

TH1

F2

F1

TR1

L
E
N

SQ1

M

M

P1

DC

SQ2

FUSE 10A

P1 

Power Plug 

F1 

Evaporator Fan

TH1 Thermostat 

F2 

Condenser Fan

C1 Compressor 

SQ1 

Control Probe

TR1 

Fan Transformers 

SQ2 

Display Probe

REFADV5-SD Undercounter Refrigerator

Содержание Advantage REFADV5-SD

Страница 1: ...your installation Should you need technical help please call our Technical Service group at 877 612 5086 or 610 252 7301 Please have your model number serial number and complete and detailed explanati...

Страница 2: ...sk of gas leak The manufacturer is not responsible for any problems due to transport executed in conditions other than those specified The equipment is secured to a wooden pallet base wrapped in a pla...

Страница 3: ...aximum size of branch circuit overcurrent device 15A breaker Refrigeration Specifications WARNING Do not damage the refrigerant circuit Refrigerant can cause personal injury and or damage refrigerator...

Страница 4: ...in the upper left side of the refrigerator 2 Remove the top and fill the bottle with a 50 50 solution of glycerine and water 3 Replace the top and probe 4 Reinsert bottle into the bracket Controller 1...

Страница 5: ...icate when the refrigeration system is required to turn on and off The refrigeration system removes heat from the cabinet interior and rejects it to the surrounding room air When the cabinet interior...

Страница 6: ...ective goggles should be worn 1 Disconnect power to unit 2 Remove rear panel 3 Remove drain pan 4 Clean drain pan with a non abrasive non chlorinated all purpose detergent 5 Reinstall drain pan 6 Use...

Страница 7: ...ture does not exceed the maximum allowable ambient temperature Check that the door is closed completely Check that the door gasket is sealing well Check that there is sufficient clearance ventilation...

Страница 8: ...Refrigerator Assembly 9 10 11 11 8 1 2 3 12 13 8 4 5 6 7 8 REFADV5 SD Undercounter Refrigerator...

Страница 9: ...aporator fan 01462258 5 Silicone blanking cap outlet pipe cover outlet pipe 01478064 6 Bottle holder glycerin bottle display probe cover 01478072 7 Shelf 2 01462316 8 Upper and lower hinge and cover 0...

Страница 10: ...10 REFADV5 SD Undercounter Refrigerator...

Страница 11: ...REFADV5 SD Undercounter Refrigerator 11...

Страница 12: ...nsequential damages expenses connecting or disconnecting charges or any losses resulting from a defect of the machine For full warranty details visit our website www follettice com productwarranties W...

Отзывы: