background image

REFVAC4P REFVAC5P

Order parts online:  

www.follettice.com 

01478106R01

801 Church Lane • Easton, PA 18040, USA

Toll free (877) 612-5086 • +1 (610) 252-7301

www.folletthealthcare.com

User Guide 

Follett Advantage

®

 REFADV5-SD 

 Undercounter Refrigerators

Welcome to Follett

Follett equipment enjoys a well-deserved reputation for excellent performance, long-term reliability and outstanding 
after-the-sale support. To ensure that this equipment delivers that same degree of service, review this guide 
carefully before you begin your installation. 
Should you need technical help, please call our Technical Service group at (877) 612-5086 or (610) 252-7301.
Please have your model number, serial number and complete and detailed explanation of the problem when 
contacting Technical Service.

Getting Started

After uncrating and removing all packing material, inspect the equipment for concealed shipping damage. All 
freight is to be inspected upon delivery. If visible signs of damage exist, please refuse delivery or sign your delivery 
receipt "damaged." Follett Customer Service must be notified within 48 hours. Wherever possible, please include 
detailed photos of the damage with the original packaging so that we may start the freight claim process.

Содержание Advantage REFADV5-SD

Страница 1: ...your installation Should you need technical help please call our Technical Service group at 877 612 5086 or 610 252 7301 Please have your model number serial number and complete and detailed explanati...

Страница 2: ...sk of gas leak The manufacturer is not responsible for any problems due to transport executed in conditions other than those specified The equipment is secured to a wooden pallet base wrapped in a pla...

Страница 3: ...aximum size of branch circuit overcurrent device 15A breaker Refrigeration Specifications WARNING Do not damage the refrigerant circuit Refrigerant can cause personal injury and or damage refrigerator...

Страница 4: ...in the upper left side of the refrigerator 2 Remove the top and fill the bottle with a 50 50 solution of glycerine and water 3 Replace the top and probe 4 Reinsert bottle into the bracket Controller 1...

Страница 5: ...icate when the refrigeration system is required to turn on and off The refrigeration system removes heat from the cabinet interior and rejects it to the surrounding room air When the cabinet interior...

Страница 6: ...ective goggles should be worn 1 Disconnect power to unit 2 Remove rear panel 3 Remove drain pan 4 Clean drain pan with a non abrasive non chlorinated all purpose detergent 5 Reinstall drain pan 6 Use...

Страница 7: ...ture does not exceed the maximum allowable ambient temperature Check that the door is closed completely Check that the door gasket is sealing well Check that there is sufficient clearance ventilation...

Страница 8: ...Refrigerator Assembly 9 10 11 11 8 1 2 3 12 13 8 4 5 6 7 8 REFADV5 SD Undercounter Refrigerator...

Страница 9: ...aporator fan 01462258 5 Silicone blanking cap outlet pipe cover outlet pipe 01478064 6 Bottle holder glycerin bottle display probe cover 01478072 7 Shelf 2 01462316 8 Upper and lower hinge and cover 0...

Страница 10: ...10 REFADV5 SD Undercounter Refrigerator...

Страница 11: ...REFADV5 SD Undercounter Refrigerator 11...

Страница 12: ...nsequential damages expenses connecting or disconnecting charges or any losses resulting from a defect of the machine For full warranty details visit our website www follettice com productwarranties W...

Отзывы: