background image

ENGLISH

operation

Add chemical solution to the liquid tank. If applying a wettable 

powder or suspension, remove retaining ring and screen from weighted 

suction tube weight. Clamp the power head in place. 

Using the measured flow rate and the dosage instructions provided 

by the chemical label or chemical manufacturer, calculate the time 

required to properly fog the area. You can control fogging time manually 

or with a timer. 

Adjust the angle of the power head for the space you are treating 

(point the nozzle slightly up for maximum distance). 

Aim fog output towards area requiring treatment. For space fogging, 

select the direction of greatest clearance so fog droplets can fill the space. 

Droplets that hit something will condense. You can also place the 

machine on a model 6100 turntable.

Confirm that flow control valve is set to the desired setting, and turn 

on fogger. 

When carrying fogger by hand, move it gently and slowly in a 

smooth arc. Sudden movements can impose excessive torque on the 

rapidly spinning fan blades and could cause premature blade failure. 

cleaning the fogger 

A. Normal cleanup. When fogging is complete, unclamp power 

head and transfer any excess chemical from the tank to an appropriate 

container. Operate the fogger for one minute with the valve open full to 

expel any liquid remaining in the fogger’s internal lines. 

B. Cleanup of difficult liquids. After fogging a viscous liquid, 

emulsion or a solids suspension, begin with a “normal cleanup” (step A). 

Then put suction tube into an appropriate solvent for your fogging 

chemical (water for water-dispersible liquids, kerosene for oil-based 

liquids, etc.) and operate unit for 1-2 minutes, flushing residual chemical 

with clean solvent. Then repeat step A.

C. Cleanup for long-term storage. Remove all liquid from tank to 

eliminate the potential for long term chemical attack on tank, suction tube 

weight, or tubing. Then follow steps A or B.

To prevent internal tubing from becoming brittle in prolonged 

storage, fog a few minutes with clean kerosene each 6-9 months, then 

clean as in step A. This will help keep tubing pliable. 

9

Содержание VECTRA-JET 750510CE

Страница 1: ...ENGLISH INSTRUCTION MANUAL VECTRA JET FOGGER Models 750510CE 750520CE READ AND SAVE THESE INSTRUCTIONS W90017505EN 04 1508...

Страница 2: ...accordance with EN55014 CISPR 14 1 2001 and CISPR 14 2 2001 Compatibility with World Electrical Systems Fogger motors and cord options KUE xxx are available for most electrical supply systems and sock...

Страница 3: ...4 Do not unplug by pulling on cord To unplug grasp the plug not the cord 5 Unplug from outlet when not in use and before servicing or cleaning 5 Do not operate any appliance with a damaged cord or plu...

Страница 4: ...r replacement of the cord or plug is necessary do not connect the equipment grounding conductor to a live terminal Check with a qualified electrician or serviceman if the grounding instructions are no...

Страница 5: ...this information obtain directions for use and safety precautions including personal protective equipment respirator face mask special clothing from the chemical manufacturer or distributor Keep an in...

Страница 6: ...izers scents or masking chemicals Humidification fogging water The liquid flow rate determines the size of the fog droplets produced Several factors influence liquid flow rate the setting of the flow...

Страница 7: ...el or information sheet Fogs are useful for this application because they diffuse widely use less chemical and speed up drying Measuring the Liquid Flow Rate Adjust the angle of the nozzle for your ap...

Страница 8: ...The top of the liner should extend over and outside the top lip of the tank NOTE Although the stainless steel of the Vectra Jet fogger offers a measure of protection against chemical corrosion we none...

Страница 9: ...dden movements can impose excessive torque on the rapidly spinning fan blades and could cause premature blade failure Cleaning the Fogger A Normal cleanup When fogging is complete unclamp power head a...

Страница 10: ...he nozzle Deposits that form on the nozzle can degrade atomization perfor mance Try to dissolve deposits with an appropriate mild solvent soapy water vinegar solution kerosene Lime Away etc Add about...

Страница 11: ...ss the motor Identify the two motor brush housings on opposite sides at the top of the motor Insert a small flat blade screwdriver between the motor wire termi nal and the plastic brush housing Gently...

Страница 12: ...s and torque ring in proper sequence The bent tab on the torque ring must face the motor and be seated in the small hole on the motor frame Reconnect electrical lines as shown on the circuit diagram R...

Страница 13: ...0 60 Hz 200 240V MODELS STANDARD UNIT CORD PLUG WITH EARTH to 220 240VAC 50 60 Hz GROUND RIVET BLUE BROWN M BLACK WHITE 100 120V MODELS STANDARD UNIT GREEN M GREEN BLUE GREEN POWER HEAD HOUSING EMI FI...

Страница 14: ...crons adjustable Liquid viscosity and surface tension affect droplet size Control Valve Nine turn vernier w memory lock Glass filled epoxy stainless stem Viton seals Liquid Capacity 1 gallon 4 L Blowe...

Страница 15: ...his warranty is limited to the original purchaser only and does not include claims for incidental or consequential damages resulting from the non function or malfunction of this product or for breach...

Страница 16: ...r respective owners In the interest of improving internal design operational function and or reliability The Fogmaster Corporation reserves the right to make changes to the products described in this...

Отзывы: