SAFETY PRECAUTIONS

Do not inhale fog output. Highly atomized liquid droplets can
float in the air a long time and are quickly absorbed by the
lungs. Depending on the material being fogged, this could result
in serious injury or death.

Do not use to apply any liquid that is hazardous to people,
animals or property when atomized into small droplets. 
The
large surface area of small droplets increases their reactivity and
potential to form an explosive mixture. Be aware of potentially
dangerous interactions between liquid fog droplets and other
aspects of the treatment area.

Read the label of the chemical you plan to use, and follow the
instructions in its “Precautions” and “Directions for Use”
sections. 
If the label lacks this information, obtain directions for
use and safety precautions including personal protective
equipment 
(respirator, face mask, special clothing) from the
chemical manufacturer or distributor.

Keep an intake air filter in place during use. This will help
prevent dust and fog droplets from entering the unit.

Do not atomize a flammable liquid. Electric arcs produced
inside the motor during normal use could ignite it. 

Do not fog near an open flame.

Risk of Electric Shock – Do not expose to rain. Store indoors.
Use only a properly grounded (earthed) three pin electric
outlet. 
The ground wire is an essential safety feature of this
product. Do not remove the grounding lug on the power cord.
Do not use an ungrounded (“3-to-2”) plug adapter. 

An extension cord, if used, must have a continuous ground
wire leading to earth and an amperage rating greater than the
rated current on the fogger nameplate label. 
Do not chain two
extension cords together. 

Содержание 6208xx

Страница 1: ...208 Pow R Jet model 6309 Micro Jet ULV model 7401 Noz L Jet model 7807 For Models 6208xx 6208xxCE 6309xx 6309xxCE 7401xx 7401xxCE 7807xx 7807xxCE showing intake filter in position READ AND SAVE THESE...

Страница 2: ...tems and socket configurations Electromagnetic Emissions Models with CE in position zz 7 8 of the part number 6208xyCE 6309xyCE 7401xyCE and 7807xyCE are shielded against the generation of ratio inter...

Страница 3: ...Do not unplug by pulling on cord To unplug grasp the plug not the cord 5 Unplug from outlet when not in use and before servicing or cleaning 5 Do not operate any appliance with a damaged cord or plug...

Страница 4: ...placement of the cord or plug is necessary do not connect the equipment grounding conductor to a live terminal Check with a qualified electrician or serviceman if the grounding instructions are not co...

Страница 5: ...information obtain directions for use and safety precautions including personal protective equipment respirator face mask special clothing from the chemical manufacturer or distributor Keep an intake...

Страница 6: ...The liquid flow rate determines the size of the fog droplets formed by the machine Several factors influence the liquid flow rate the density and viscosity of the liquid the setting of the flow contr...

Страница 7: ...gressively larger droplets wet fog fine mist Liquid flow is regulated by a control valve or for certain models a fixed flow restrictor in the liquid intake line Calibration Adjust the angle of the noz...

Страница 8: ...ive plastic tank liner and position it inside tank new units ship with a tank liner in place The top of the liner should extend over and outside the top lip of the tank Add fogging liquid to the tank...

Страница 9: ...oth arc Sudden movements can impose excessive torque on the rapidly spinning fan blades and could cause premature blade failure Cleaning the Fogger A Normal cleanup When fogging is complete remove the...

Страница 10: ...80 for a package of 10 Cleaning the nozzle Deposits which form on the nozzle can degrade performance Try to dissolve deposits with an appropriate mild solvent soapy water vinegar solution kerosene etc...

Страница 11: ...move front housing see Simple Workstation to access the motor Identify the two motor brush housings on opposite sides at the top of the motor Insert a small flat blade screwdriver between the motor wi...

Страница 12: ...in proper sequence Take care that the bent tab on the torque ring faces the motor and is seated in the small hole on the motor frame Reconnect electrical lines as shown on the circuit diagram Replace...

Страница 13: ...pen this style press release tab and pull fitting apart The other style uses a locking collet with spring clips inside the receptacle to secure the connector To open this style connector release the l...

Страница 14: ...0 60 Hz 240V MODELS STANDARD UNIT CORD PLUG WITH EARTH to 220 240VAC 50 60 Hz GROUND RIVET BLUE BROWN M BLACK WHITE 120V MODELS STANDARD UNIT GREEN M GREEN BLUE GREEN POWER HEAD HOUSING EMI FILTER CE...

Страница 15: ...Rate 7401 0 10 oz 300 ml min adjustable 7807 0 10 oz 300 ml min adjustable plus liquid ON OFF toggle valve on wand 6208 0 10 oz 300 ml min adjustable 6309 10 oz 300 ml min not adjustable a Droplet Siz...

Страница 16: ...and oil resistant vinyl Fittings brass stainless steel optional Nozzle Celcon acetyl copolymer Dimensions LxHxDia 12 5 x 15 4 x 8 6 in 32 x 39 x 22 cm Hose Wand 7807 36 in 91 cm hose and either 38 in...

Страница 17: ...ified voltage This warranty is limited to the original purchaser only and does not include claims for incidental or consequential damages resulting from the non function or malfunction of this product...

Страница 18: ...n Celcon and Viton are registered trademarks of their respective owners In the interest of improving internal design operational function and or reliability The Fogmaster Corporation reserves the righ...

Отзывы: