Compliance Information Statement: Declaration of Compliance procedure

Product Identification:      Focusrite RedNet
Responsible party:             American Music and Sound
Address:                              4325 Executive Drive
                                              Suite 300
                                              Southaven
                                              MS 38672
Telephone:                           800-431-2609
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause 

harmful  interference,  and  (2)  this  device  must  accept  any  interference  received,  including  interference  that  may  cause  undesired 

operation.

For USA

To the User:

1. Do not modify this unit! This product, when installed as indicated in the instructions contained in this manual, meets 

FCC requirements. Modifications not expressly approved by Focusrite may void your authority, granted by the FCC, to 

use this product.

2. Important: This product satisfies FCC regulations when high quality shielded cables are used to connect with other 

equipment. Failure to use high quality shielded cables or to follow the installation instructions within this manual may 

cause magnetic interference with appliances such as radios and televisions and void your FCC authorization to use this 

product in the USA.

3. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to 

part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a 

commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed 

and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of 

this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct 

the interference at his own expense

For Canada
To the User:

This Class A digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

The exclamation point within an equilateral triangle is intended to alert the user 

to the presence of important operating and maintenance (servicing) instructions 

in the literature accompanying the appliance.

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS 

TO RAIN OR MOISTURE AND OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHOULD NOT BE 

PLACED ON THIS APPARATUS.

The lightning flash with arrowhead symbol, within equilateral triangle, is intended 

to alert the user to the presence of uninsulated “dangerous voltage” within the 

product’s  enclosure  that  may  be  of  sufficient  magnitude  to  constitute  a  risk  of 

electric shock to persons.

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER 

(OR BACK). NO USER-SERVICEABLE PARTS INSIDE. 

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

RoHS Notice

Focusrite Audio Engineering Limited has conformed where applicable, to the European Union’s Directive 2002/95/EC on Restrictions 

of Hazardous Substances (RoHS) as well as the following sections of California law which refer to RoHS, namely sections 25214.10, 

25214.10.2, and 58012, Health and Safety Code; Section 42475.2, Public Resources Code.

ENVIRONMENTAL DECLARATION

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

Содержание RedNet MP8R

Страница 1: ...User Guide www focusrite com FFFA001146 01 ON...

Страница 2: ...cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13...

Страница 3: ...d if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful inte...

Страница 4: ...Power Requirements 12 REDNET MP8R OPERATION 13 First Use and Firmware Updates 13 Digital Clocking 13 Pull Up and Pull Down Operation 13 Front Panel Control Lockout 13 Gain Compensated Outputs 13 OTHER...

Страница 5: ...e to read through the System User Guide so that they are fully aware of all the possibilities that RedNet and its software have to offer Should either User Guide not provide the information you need b...

Страница 6: ...twork failure These ports may also be used to daisy chain additional units when operating in Switched mode Separate power input sockets on the rear panel allow one supply to be connected to an uninter...

Страница 7: ...s from the preamps and channels 9 16 the compensated outputs Gain compensation can be enabled individually for each mic channel Headroom Allowance If during a performance an analogue mic level was red...

Страница 8: ...id sync signal is received from the network or the RedNet MP8R is network master 4 RedNet Sample Rate Indicators Five orange indicators 44 1 kHz 48 kHz x2 multiple of 44 1 or 48 x4 multiple of 44 1 or...

Страница 9: ...IP addresses secondary Unit MAC addresses primary Unit MAC addresses secondary Firmware Version for the unit Device name 48V Switches phantom power on for selected channel 2 4 k Selects low input imp...

Страница 10: ...or the Dante network Use standard Cat 5e or Cat 6 network cable to connect to a local Ethernet switch to connect the RedNet MP8R to the RedNet network Adjacent to each network socket are LEDs which il...

Страница 11: ...t installed the retaining clips will need to be attached to the power input sockets on the rear panel Insert each clip by squeezing together the legs as shown in the first image below aligning the pin...

Страница 12: ...er Also ensure that when mounted in a rack the side vents are not obstructed Power Requirements RedNet MP8R is mains powered It incorporates Universal power supplies which can operate on any AC mains...

Страница 13: ...r pull down percentage as selected in the Dante Controller application Front Panel Control Lockout To prevent accidental adjustment of any control that could affect a channel s audio level the MP8R fr...

Страница 14: ...t Control image The signal level gain and input function settings are indicated for each channel PSUs A B Each illuminates if PSU has power input and all DC outputs are present Networks Each illuminat...

Страница 15: ...The default is Off 16 channels are available allowing a maximum of 16 independent RedNet MP8R control paths Two devices should not be set to the same MIDI channel MIDI channel selection is saved with...

Страница 16: ...RJ 45 receptacle Applies to Ethernet Dante XLR Connectors Connector type XLR 3 receptacle Applies to Audio Input Pin Cat 6 Core 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 Whit...

Страница 17: ...B A Weighted typical Rs 150 Phantom Power 48V independently switchable per channel Pad 20dB independently switchable per channel High Pass Filter 6dB 65Hz 3Hz 12dB Octave independently switchable per...

Страница 18: ...port will cause this LED to illuminate Secondary network Green LED Indicates that a network connection is present on secondary port when in redundant mode Not used in switched mode Sync Lock Green LE...

Страница 19: ...opriate procedure for resolving the warranty issue In every case it will be necessary to provide a copy of the original invoice or store receipt to the distributor In the event that you are unable to...

Отзывы: