Situation 2 – Single Pro Tools system with both RedNet 5s and other Pro Tools interfaces
RedNet 5
Gigabit Swit
ch
RedNet 5
Set the same RedNet 5 as
Network Master
Set a RedNet 5 as
Pro Tools clock source
Ethernet cable
Pro Tools HD
DigiLink cable
Pro Tools HD I/O
Pro Tools HD I/O
Sync
Other RedNet
Interface
Other RedNet
Interface
Other RedNet
Interface
Other RedNet
Interface
LOOP SYNC OUT
LOOP SYNC OUT
LOOP SYNC IN
LOOP SYNC IN
RedNet 5
Gigabit Swit
ch
RedNet 5
Set the RedNet 5 with
LOOP SYNC IN connected,
as Network Master
Set a Pro Tools interface
as a Pro Tools clock source
Ethernet cable
Pro Tools HD
DigiLink cable
Pro Tools HD I/O
Pro Tools HD I/O
Sync
Set the clock source for
the same RedNet 5 to
“LOOP SYNC”
Other RedNet
Interface
Other RedNet
Interface
Other RedNet
Interface
Other RedNet
Interface
LOOP SYNC IN
LOOP SYNC IN
LOOP SYNC OUT
LOOP SYNC OUT
Pro Tools|HD I/O audio interfaces may be used as audio I/O on the same Pro Tools system
as RedNet 5s. Choose the audio interface you wish to be the clock source. This may be either a
RedNet 5 or a Pro Tools audio interface.
If a RedNet 5 is to be the clock source:
1. It is recommended that the same Rednet 5 is set in RedNet Control as the RedNet network
master .
2. Connect a BNC cable between the LOOP SYNC OUT of any of the RedNet 5s to the LOOP SYNC
IN of one of the Pro Tools audio interfaces.
3. Connect additional BNC cables between the LOOP SYNC OUT of the ‘first’ Pro Tools|HD I/O
audio interface and the other Pro Tools interfaces, in the usual ‘daisy-chain’ manner.