![Focusrite Green Range Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/focusrite/green-range/green-range_manual_2314517009.webp)
The Controls
The Comp button switches the compressor in or out.
The Comp to Meter button modifies what the meter displays, and how it displays it
When the switch is out, the meter acts as a VU meter displaying the level of the
input signal. It displays the signal in bar mode (that is, the meter lights all the
LEDs up to the signal level, thus creating a bar effect).
When the switch is in, the meter acts as a peak meter displaying the amount of
compression. It displays the compression in dot mode (that is, the meter lights
only the LED for the signal level). Since compression reduces the volume of the
signal, the meter drops as compression is applied: for example, a 3 dB drop
shows as -3 VU on the meter. The change to peak action means that it is easy
to see when transients occur (which will be compressed more heavily).
The Ratio and Threshold controls set the amount of compression applied to the
signal (see below).
The Make-up gain sets the output volume of the compressed signal (see below).
The Auto Rel button sets an automatic release time for the compressor (see below).
v o i c e b o x
10
Threshold
Comp
dB
12
-24
-17
-10
-2
5
Make up
Compressor
dB
20
0
4
8
12
16
Ratio
1.5
3
5
7
10
Comp
To Meter
Auto
Rel