Miscellaneous Settings
MENU
The default password is: UP - DOWN - UP - DOWN - ENTER
KEY:
In the menu
KEY
the password protection of the fixture is activated or deactivated. If set
ON
the
fixture is password protected when started. 30 seconds after the last setting the menu is locked
again. To be able to make changes in the menu the password
UP - DOWN - UP - DOWN - ENTER
needs to be typed in.
DIMMER:
controls different dim curves to simulate a halogen bulb (
DIM4/DIM3/DIM2/DIM1/OFF
).
PERFORM:
gives the user the opportunity to change the performance of the fan between
LIVE
,
STUDIO
and
POWER
. In
STUDIO
mode the fan is run on low noise. In case of overheat the intensity
of the led module is regulated down. In
LIVE
mode, fan speed and the intensity of the led module is
balanced with each other to reach the best output with as low fan speed as possible. In
POWER
mode the temperature of the fixture is primary regulated by the fan, to keep a high intensity as long
as possible.
XY OFFSET:
activates (
SHOW
) or deactivates (
HIDE
) the possibility to adjust the preset PWM-
frequencies in the menu.
PWM:
gives the user the possibility to adjust the PWM frequency of the LEDs (
1200HZ/2400HZ
/
4000HZ
/
6000HZ
/
25000HZ
).
FULL POWER CCT:
sets the colour temperature at maximum output.
3200K/4200K/5600K/10000K
and
NORMAL
can be set.
DMX ERROR:
sets how the fixture responses if DMX-signal gets lost. Set
SAVE
to hold the last
received value or
BLACK
for blackout.
RESET:
sets all editable settings back to factory default.
E-28
PERSON
SETTING
****
OFF
KEY
DIMMER
DMX ERROR
DIM4
DIM3
DIM2
DIM1
OFF
SAVE
BLACK
1200HZ
2400HZ
4000HZ
6000HZ
25000HZ
3200K
4200K
5600K
10000K
NORMAL
PWM
FULL POWER CCT
ON
PERFORM
LIVE
STUDIO
POWER
HIDE
SHOW
XY OFFSET
OFF
RESET
****
OK
X FINE
Y FINE
+/-200
+/-200