This fire has been designed to be installed in two main applications; either to fit into a suitable opening created in the inner leaf
of an outside wall or false chimney breast/extended fire surround built to conceal the appliance. The appliance can also be fitted
into an unserviceable or inoperative fireplace served by a natural draught flue, however in this situation the old flue MUST be
sealed off. It will be necessary to ventilate the old flue to prevent condensation and dampness forming. Any air vent used to ven-
tilate the old flue must not be sited within 1 metre of this appliance. If the flue can be ventilated to the outside of the building
then this is usually the best solution. If in doubt then advice should be sought from a local building control officer.
The appliance must be installed onto a suitable non-combustible insulating surface at least 12 mm thick covering the entire base
area of the box. The fire must be used with a back panel capable of withstanding 150°C minimum. Any combustible materials
directly behind the fire frame (or back panel) and close to the cavity box of the fire must be removed and replaced with non-
combustible material such as cement, browning, 'Superlux' board or equivalent materials.
Propane/LPG models must not be installed in cellars, basements or any room which is completely below ground level.
The room size should be a minimum of 27m
3
(e.g. 11’ x 11’ x 8’) to allow adequate circulation of air and ensure the correct oper-
ation of the fire. This volume may include adjacent spaces but these spaces must not be separated by a door. To calculate a room
size in cubic metres (m
3
) divide the room volume in cubic feet (ft
3
) by 35.3.
This appliance may be installed in any room in the home except bathrooms or bedrooms. Installation in living rooms is common,
however other rooms such as kitchens, dining rooms and hallways are permitted, providing a suitable natural gas supply is avail-
able, and rooms sizing and ventilation requirements are strictly adhered to (see sections 3.1 and 4.1).
The appliance is designed to be versatile, and as such will operate correctly when exposed to normal gentle draughts experienced
within the home. It is not recommended, however that the appliance be installed in areas where it is likely to be exposed to per-
sistent strong draughts, that may be generated by outside doors or windows, air vents etc. It is recommended that the appliance
should not be installed within 1 metre of any air vent.
©
2013 Focal Point Fires plc.
2.0 APPLIANCE DATA
GB IE
Please see Data Badge affixed to appliance for current data.
This appliance is for use only with the gas type, and at the pressure stated on the appliance Data Badge.
3.0 INSTALLATION REQUIREMENTS
3.1 ROOM SIZING
4.0 SITE REQUIREMENTS
3
Model
Destination
Country
Cat
Operating/Inlet Pressure
(±2.0 mbar)
Max Energy Input (kW) Min Energy Input (kW)
G20 G25 G30 G31
Gross
Net
Gross
Net
PI27 - Natural Gas
GB - IE
I2H
20
-
-
-
2.3
2.1
1.3
1.15
Specifications
PI27 - Natural Gas Models
Main burner Flow Restrictor
Stereo 1.09
Oxypilot
SIT 9110
Gas Control
Copreci 21400
Gas Inlet
8mm restrictor elbow
Ignition
Double Piezo Spark
Spark Gap
3.5 - 4.5mm