8.0 INSTALLATION WALL MOUNTED - CONTINUED

9.0 OPERATING THE APPLIANCE 

GB IE

8

©

2019 Focal Point Fires plc.

The control panel is on the right side of the unit.

When a function is changed from the control panel or remote there will be a corresponding indicator displayed. The indicator shows the

function changed and the level selected. When the function is turned off, the corresponding indicator will fade off.

Securing the front fascia.
1. Locate the hole on both left and right sides and insert a

screw through the hook, into the fireplace insert.
2. Tighten screw to pass it through the hook, on both sides.
3. Ensure the front fascia is secure.
Note: Tighten up the screw carefully, to avoid damage to the

front panel.

1. ON/OFF

2. HEATER

3. TIMER

4. BRIGHTNESS

5. CHILD SAFETY LOCK

6. PLUS

7. MINUS

1.

3.

6.

5.

4.

2.

1.

2.

3.

4.

7.

Power Button

This button will not only put the fireplace insert in a standby mode, but also you

can see the flame effect through the screen. This will turn off all functions at once.
Heater 

The fireplace contains a fan forced heater.

The default setting temperature is 72°F (22°C).

The thermostat setting range is 50°-86°F or 10°-30°C.

The thermostat is adjustable by 2°F or 1°C increments.

To change between °F and °C press and hold the Heater button for 5 seconds.

Timer

Pressing the timer button repeatedly will cycle through the following timer          

settings: 30 minutes, 1 hour, 2 hr, 3 hr, 4 hr, 5 hr, 6 hr, 7 hr, 8 hr and off.

The fireplace will automatically turn off when the timer reaches zero minutes.

1.

Содержание EBONY ELECTRIC

Страница 1: ...BT Tel 01202 499330 Fax 01202 499326 www focalpointfires co uk Email sales focalpointfires co uk MODEL SHOWN EBONY LED ELECTRIC FIRE This product is only suitable for well insulated spaces or occasion...

Страница 2: ...d from 3 years and less than 8 years shall only switch on off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision...

Страница 3: ...r obstruct the heater in any way Overheating will result if it is accidentally covered Never immerse the product in water or any other liquids DO NOT use the appliance outdoors Before cleaning the app...

Страница 4: ...ind a more suitable wall location DO NOT mount on a ceiling or floor recess any part of the appliance into the wall or run the supply cable under carpets site any electrical equipment e g plasma scree...

Страница 5: ...plastering and or dry wall sanding and wall painting has been completed Do not block the ventilation holes of the appliance The wall onto which the appliance is installed must be flat Install only on...

Страница 6: ...Use two of the metal plate screws to fix each of the metal fixing plates to the firebox 4 Ensure the metal fixing plates are securely attached Installing the wall plugs into the wall 1 Drill 5 holes...

Страница 7: ...the fire is secured to the wall Installing the front fascia 1 Hold the glass fascia securely and hang it onto the firebox hooks which are located on both sides of the firebox 2 The glass fascia should...

Страница 8: ...en up the screw carefully to avoid damage to the front panel 1 ON OFF 2 HEATER 3 TIMER 4 BRIGHTNESS 5 CHILD SAFETY LOCK 6 PLUS 7 MINUS 1 3 6 5 4 2 1 2 3 4 7 Power Button This button will not only put...

Страница 9: ...e first digit of the digital tube will start to flash then press and button to set the hour 10 for example 3 Press a third time the first digit of the digital tube will stay on and the last digit of t...

Страница 10: ...on a certain day of the week you need to press the timer key continuously for four times to skip this day For example you do not need to set on off status on Tuesday When the Monday timer setting is...

Страница 11: ...information about collecting and recycling used batteries please contact your local municipality your waste disposal service or the store where you purchased this product 10 0 SAFETY CUT OUT SYSTEM NO...

Страница 12: ...t thermostat sensor 2019 Focal Point Fires plc 13 0 SERVICING There are no internal user serviceable parts Check regularly for security of wall fixings as appropriate Also check security of supply cab...

Страница 13: ...ve a firm cost until we commence the repair as it is not always possible to identify which components have been damaged Repaired or replaced products are covered only for the remainder of the original...

Отзывы: