CLEANING

Before carrying out any of the following operations, ensure that the fire is OFF and completely cold.

Debris that may form on the fuelbed should be periodically removed by a competent person. Large deposits could indicate deterioration of
the flue. This should be repaired by a competent person, and the fire serviced before  further use.

FIREFRONT - Any dust accumulating in the firefront may be removed using a vacuum cleaner or dry cloth. Heavy stains may be removed by
using a damp cloth and mild household detergent. Brass parts of the firefront may be cleaned using a suitable brass cleaner. Replace the front
centrally against the fire after cleaning.

PAINTED AREAS - These can be cleaned using a dry cloth.

CLEANING THE CERAMIC PARTS

Remove the firefront  and place to one side. Remove the ceramic components. Gently clean in the open air. Be careful not to create dust
from the ceramics. Where necessary replace damaged components with genuine spares. Seal scrap ceramic components in plastic bags
and dispose at proper refuse sites as directed.

Re-fit the ceramic parts by referring to the relevant section of these instructions.

SERVICING

The fire and flue should be checked on an annual basis to ensure all of the product of combustion are entering the flue and that there is no
excessive build up of soot. The frequency of service will depend on usage, but MUST be carried out at least once annually. Servicing must
be carried out by a competent person, such as a CORGI registered installer.

Cleaning of the coals/pebbles may be carried out by following the instructions given in the Installation section. The Installation instructions
carry full servicing details for the use of the installer.

If debris from the flue or other foreign matter is found on the fire it may indicate a need for servicing. Do not use the fire until the source of
the debris has been found and rectified.

Air vents (where fitted) should be checked periodically to ensure they are free from obstruction.

LIST OF SPARES

PART NO.

ITEM

F780094

Pack of 15 coals

F550057

Pack of 15 pebbles

F780093

Ceramic combustion matrix (coal)

F780035

Ceramic combustion matrix (pebble)

F550208

Ceramic pad set (includes rear pad, taper pad and side cheeks)

Please Enquire

Decorative Frame

Please Enquire

Decorative Front

3

7.0

8.0

9.0

10.0

As our policy is one of continuous improvement and development , we hope therefore you will understand we must retain the right to amend
details and/or specifications without prior notice.

F860212

©

2008 Focal Point Fires plc.

Содержание BLENHEIM STYLE

Страница 1: ...ser for safekeeping Revision C 10 08 Country s of destination GB IE MULTIFLUE GAS FIRE RANGE BLENHEIM STYLE ELEGANCE LULWORTH Focal Point Fires plc Christchurch Dorset BH23 2BT Tel 01202 499330 Fax 01...

Страница 2: ...ad all these instructions before commencing installation This appliance must be installed in accordance with the rules in force and only used in a suf ficiently ventilated space The appliance is desig...

Страница 3: ...e installation and use of this appliance This appliance is free from any asbestos material Refractories and coal bed are constructed from ceramic fibre 1 Section 1 0 2 0 3 0 4 0 4 1 5 0 6 0 7 0 7 1 8...

Страница 4: ...more than one appliance i e not shared with a gas back boiler There must be no opening in the flue apart from the one that the appliance is installed into and the one venting the gases into the air A...

Страница 5: ...t at the back of the appliance must have a 50mm mini mum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet must form a smooth path in...

Страница 6: ...FABRICATED FLUE BOXES This appliance can be fitted into a number of proprietary flue boxes provided that the minimum dimensions given in the diagram below are complied with Constructional Note The fra...

Страница 7: ...in the rubber to slip snugly around the outside of the supply pipe and sleeving Note DO NOT install or use the appliance without this seal in place If the hole is inadvertently opened reseal with an...

Страница 8: ...pe at its ends The open end of the gas supply pipe should be temporarily sealed to prevent ingress of dust and dirt during installation CABLE FIXING Drill four holes using a 8mm masonry bit to a depth...

Страница 9: ...d firefront will clear the supply route If the data control plate is not already fitted attach with two screws ensuring the control knob is free to be depressed fully FUEL BED LAYOUT Fit the tapered b...

Страница 10: ...t row of six pebbles on to the matrix Ensure the pebbles are firmly against the side cheeks as shown in the photograph If necessary pull the peb bles forward slightly to ensure their rear edges do not...

Страница 11: ...nition sequence as previously described and after turning the control knob through the spark position the knob should be held in and the pilot lit with a taper SETTING PRESSURE To commission the appli...

Страница 12: ...will emit a newness smell for a time after initial commissioning and that extra ventilation may be needed during this time Advise that the fire is fitted with a spillage safety device O D S If the fir...

Страница 13: ...e cleaning easier Do not damage or try to remove the pilot injector The unit is factory set and the only check necessary is to ensure the spark gap is correct See specifications for gap setting REMOVI...

Страница 14: ...or infirm are concerned Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper may discolour if fitted too close to the fire See relevant sectio...

Страница 15: ...OT light position ensur ing the pilot has lit If not return the knob clockwise and repeat When the pilot lights after the spark keep the knob depressed for approximately ten sec onds Now release the k...

Страница 16: ...lue should be checked on an annual basis to ensure all of the product of combustion are entering the flue and that there is no excessive build up of soot The frequency of service will depend on usage...

Отзывы: