CLEARANCES TTO C
COMBUSTIBLES
A non-combustible shelf may be fitted to within 100mm of the top edge of the fire frame. However the items
placed on it must also be able to withstand high temperatures.
A combustible shelf may be fixed to the wall above the fire, providing that is complies with the dimensions
given below.
Combustible materials, such as wood, may be fitted to within 100mm (4in) of either side of the frame of the
appliance, providing the forward projection does not exceed 100mm (4in).
Any combustible side walls must be at least 500mm to the side of the radiant heat source.
As with all heating appliances, any decorations, soft furnishings and wall coverings (i.e. flock, blown vinyl and
embossed paper) positioned too close to the appliance may discolour or scorch.
VENTILATION
No purpose provided ventilation is required for this appliance because it is room sealed. The requirements of
other open flued appliances operating in the same room or space must be taken into consideration when
assessing ventilation.
The combustion air supply for this appliance is ducted from the outside air by an integral flue system. The ter-
minal of this flue system must always be kept clear of vegetation, new buildings, conservatories, extensions,
sheds or other potential obstructions and able to perform its function correctly. A supply of fresh air into the
room is advisable to maintain temperatures within limits.
For Republic of Ireland, see relevant rules in force.
OPERATING IINSTRUCTIONS
The pilot is visible through the small hole in the left hand side of the matrix
base. Push in and turn the control knob to the SPARK position, and hold
there for a few seconds.
Continue turning anti-clockwise through the spark click to the PILOT light
position, ensuring the pilot has lit. If not, return the knob clockwise and
repeat.
When the pilot lights after the spark, keep the knob depressed for approxi-
mately ten seconds. Now release the knob and the pilot should stay alight.
If the pilot is extinguished during use of the fire, you MUST wait three min-
utes before repeating the ignition procedure.
To achieve the HIGH setting, push the control knob in slightly and continue tuning anti-clockwise to the high
position. The main burner should light after a few seconds. To decrease the setting to LOW, turn the control
knob clockwise to the low setting.
To turn to the PILOT position from the HIGH or LOW positions, press the control knob in slightly, and return
to the pilot position and release. To turn the fire OFF, keep the knob pressed in, return to the off position and
release. If the fire is switched off during use, ALWAYS wait 3 minutes for the fire to cool safely before attempt-
ing to relight. This ensures the safest condition for re-ignition.
To turn the fire OFF, keep the knob pressed in, return to the off position and release.
CLEANING
Before carrying out any of the following operations, ensure that the fire is OFF and completely cold.
Debris that may form on the fire bed should be periodically removed by a competent person. Large deposits
could indicate flue problems or incorrect coal placement. This should be repaired by a competent person and
the fire serviced before further use. To gain access to the fire bed, remove the hood and glass door assembly.
Maximum depth of shelf
Minimum distance from hearth to underside of shelf
180mm
850mm
1.0
1.0
1.0
1.0