OPERATING THE APPLIANCE
Read All Instructions Before Use
Check that the heater outlet grille, mounted at the top of the appliance, is not covered or obstructed in any way,
and ensure the power to the fire is switched on. The appliance is controlled using four switches mounted at the
right hand side towards the top.
The first switch towards the front, marked (0I), controls the main power to the appliance and switches on the
visual light display. This feature can be used independently of the heating features.
The next switch marked (*) operates the fan blower without heat, and can be used for cool air circulation.
However for this feature, the main power switch (0I) must also be in the “on” position.
The next switch with a “single bar” marked (I) operates the low heat, (1kW), setting.
The switch with “two single bars” marked (II) operates the high heat (2kW) setting.
To operate the fire in any of the above modes, the left hand switch marked (OI) must be switched to the “on”
position.
To operate the fire, the first switch must be turned on firstly, followed by the second switch to start the blower,
if required. To obtain heat from the appliance, the I switch must then be operated for LOW heat, followed by
the II switch for the HIGH heat setting.
The appliance can be switched off at any time, irrespective of the particular mode selected, by simply switch-
ing the first switch marked (OI) to the “off” position.
It is also recommended to unplug the power supply cable at the supply outlet when not in use.
SAFETY CUT-OUT SYSTEM
This appliance has a safety cut-out system fitted which will activate if the air inlets or heater outlets are obstruct-
ed. For safety reasons the fire WILL NOT switch on again automatically.
NOTE: The visual light effect will remain operational if the cut-out is activated, only the fan heater elements are
prevented from operating.
The following procedure must be carried out before the fire can be operated again:
1. Unplug the power supply cable at the outlet socket and place all switches to off at the appliance.
2. Leave the fire OFF for a period of not less than 10 minutes, ensuring any obstructions are removed.
3. Plug in the power supply cable at the outlet socket, and then switch on at the appliance.
If the appliance fails to operate correctly, repeat the above procedure.
If an attempt to switch on is made before the safety cut-out has reset, the heaters may cut-out for a further peri-
od of time. If the sequence has been followed correctly and the heaters still fail to function, check the power
supply cable plug is plugged in at the outlet socket. If this is not the cause, call an electrician.