The mounting depth of this appliance is 108mm.

In accordance with BS 5871 part 2, minimum debris collection volumes are required behind the installed appliance. These are shown in the
table below and as dimension X on the fireplace diagram shown previously.

CLAY/CEMENT LLINES O

OR BBLOCK FFLUE W

WHICH IIS N

NEW, U

UNUSED, O

OR PPREVIOUSLY O

ONLY U

USED W

WITH A

A G

GAS FFIRE.

X D

Dimension == 220mm

UNLINED  FFLUE O

OR C

CHIMNEY W

WHICH H

HAS BBEEN PPREVIOUSLY U

USED FFOR A

A SSOLID FFUEL O

OR O

OIL BBURNING A

APPLIANCE

X D

Dimension == 660mm

VENTILATION

No ppurpose pprovided vventilation iis nnormally rrequired ffor tthis aappliance. The requirements of other appliances operating in the same room or
space must be taken into consideration when assessing ventilation.

If spillage is detected when commissioning the appliance, then amongst other problems there may be insufficient natural ventilation for cor-
rect operation of the flue. If the appliance does not spill with the windows open, but spillage is detected with the windows closed, this demon-
strates a lack of natural ventilation. If spillage is still detected with the windows open, the flue is at fault. Installation of an air brick is the best
solution to lack of ventilation. Any ventilation fitted must comply with BS 5871 part 2 and BS 5440 part 2.

Spillage detected during commissioning is almost always a result of poor flue performance that cannot be corrected by any amount of venti-
lation.

For Republic of Ireland ventilation may be required, see IS 813, ICP3, IS 327, and any other rules in force.

PREFABRICATED FFLUE BBOXES

This appliance can be fitted into a number of proprietary flue
boxes provided that the minimum dimensions given in the
diagram below are complied with.

Constructional N

Note: The frame of the fire, any back panel or

other infill panels, and the flue box must be sealed together
so that there is no possibility of leakage between them.
Adequate clearances to combustible materials (e.g. false
chimney breast construction) must be maintained.

The  m

manufacturers’  iinstructions  ffor  ffitting  tthe  pprefabricated

box sshall bbe ccomplied w

with aat aall ttimes.

To fit the fire using the cable fixing kit, some minor adaption
may be necessary for certain flue boxes. A check should be
made to ensure the firebox does not obscure the flue box
outlet.

The firebox, base of the flue box, and hearth below may be
drilled to allow plugs and screws to secure installation.

It is important that the sealing requirements of the appliance
are met at all times and that the flue box is well sealed to any
back or infill panel.

Note: The DEPTH dimension is inclusive of any back or infill panel.

UNPACKING THE APPLIANCE

Stand the carton the right way up, cut the strapping bands and remove the top endcap. Read all the instructions before continuing to unpack
or install this appliance.

Remove the box ceramic combustion matrix, side cheeks and the bags containing the coals/pebbles. Remove the cardboard packing pieces,
and any other bags or boxes containing fittings or other parts. When all loose parts have been removed, the outer sleeve may be lifted off to
reveal the appliance. Check that the components supplied correlate with the component checklist given in section 7.1. Please dispose of all
the packaging materials at you local recycling centre.

4

4.1

5.0

6.0

125mm min internal
dia twin wall flue

540mm min
opening height

350mm min open-
ing width

128mm
min
depth

7.0

Содержание LULWORTH LPG

Страница 1: ...S F FIRE Focal Point Fires plc Christchurch Dorset BH23 2BT Tel 01202 499330 Fax 01202 499326 www focalpointfires co uk e mail sales focalpointfires co uk All i instructions m must b be h handed t to...

Страница 2: ...Lulworth LPG...

Страница 3: ...led by a competent person in accordance with Gas Safety Installation and Use Regulations 1998 It is strongly recommended that a CORGI registered engineer be used for this purpose Read all these instru...

Страница 4: ...iently y v ventilated s spac ce Consult a all i instruc ctions b before i installation a and u use o of t this a applianc ce This a applianc ce i is f free f from a any y a asbestos m material R Refra...

Страница 5: ...lled The flue must be connected to only one fireplace and the flue must not vent more than one appliance i e not shared with a gas back boiler There must be no opening in the flue apart from the one t...

Страница 6: ...liance must have a 50mm minimum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet must form a smooth path into the flue Any type of f...

Страница 7: ...iance can be fitted into a number of proprietary flue boxes provided that the minimum dimensions given in the diagram below are complied with Constructional N Note The frame of the fire any back panel...

Страница 8: ...nugly around the out side of the supply pipe and sleeving Note D DO NOT install or use the appliance without this seal in place If the hole is inadvertently opened reseal with an intact grommet Failur...

Страница 9: ...h fireplace openings Any sleeving should be sealed to the pipe at its ends The open end of the gas supply pipe should be temporarily sealed to prevent ingress of dust and dirt during installation CABL...

Страница 10: ...ough the spark click to the PILOT light position ensuring the pilot has lit If not return the knob clockwise and repeat When the pilot lights after the spark keep the knob depressed for approximately...

Страница 11: ...cating doors open Finally repeat with all doors open BRIEFING T THE C CUSTOMER All instructions must be handed to the user for safekeeping Show the customer how to light and control the fire After com...

Страница 12: ...e the tubing nut from the valve end of the pilot pipe and blow through to dis lodge any debris Clean the exterior of the pilot assembly with a soft brush and blow through the flame ports on the pilot...

Страница 13: ...f for a a t time a and t then c cuts o off Excessive room draught or flue pull rectify Loose or faulty thermocouple rectify ODS system in operation Firebox grommet seal not fitted rectify Lint in pil...

Страница 14: ...he elderly or infirm are concerned Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper may discolour if fitted too close to the fire See rele...

Страница 15: ...in force OPERATING I INSTRUCTIONS The pilot is visible through the left hand side of the matrix Rotate the coals pebbles for good viewing Push in and turn the control knob to the SPARK position and h...

Страница 16: ...s ensure that the fire is OFF and completely cold Debris that may form on the fuelbed should be periodically removed by a competent person Large deposits could indicate deterioration of the flue This...

Отзывы: