FLUE SPILLAGE MONITORING SYSTEM

This fire is fitted with a flue spillage safety device (ODS). If the fire shuts down during use for no apparent reason then several things may be
suspected. If a door or window has been opened creating a draught, then pilot disturbance is the problem, and removal of the draught should
resolve this. The gas pressure reaching the fire must also be checked (again, recall your installer to check and rectify any problem). The ther-
mocouple connection into the back of the gas control valve may also have worked loose during installation, simply get the installer to tight-
en.

If pilot disturbance is not the cause, then the ODS safety system may be in operation. Switch the appliance OFF, check the flue and carry out
any remedial work required. Relight the fire and carry out a spillage test. DO NOT allow the appliance to be used if it continues to fail a
spillage test.

The aeration hole of the pilot must be carefully cleaned out on each annual service to ensure continued function of the ODS.

The spillage monitoring system shall not be adjusted, modified, or put out of operation by the installer. Any spare parts fitted MUST be of a
type supplied for the purpose by the appliance manufacturer.

If the fire is not spilling, then further guidance should be sought, using the Troubleshooting section as a guide.

TESTING FOR SPILLAGE

Close all doors and windows to the room containing the appliance. Let the fire run on HIGH for five minutes. Take a smoke match, light it,
and using a smoke match tube, hold it at the top edge of the fire opening, 25mm down and 25mm in. Starting 50mm in from either side, run
the smoke match across the opening. All the smoke should be drawn away up the flue. Any smoke returning into the room indicates that
spillage is occurring. If the initial spillage test fails, run the fire for a further 10 minutes and repeat the test. When the test has been complet-
ed satisfactorily, repeat with any extractor fans in the premises running on the highest setting, and any communicating doors open. Finally,
repeat with all doors open.

BRIEFING TTHE C

CUSTOMER

All instructions must be handed to the user for safekeeping. Show the customer how to light and control the fire.

After commissioning the appliance, the customer should be instructed on the safe use of the appliance and the need for regular servicing.
Frequency of service depends on usage, but MUST be carried out at least once annually.

Advise that cleaning of the fire may be achieved when the fire is cold using a damp cloth and mild detergent on most surfaces.

Scratched and other superficial damage to the matt black paintwork of the appliance can be covered with matching heatproof spray. Use
only the manufacturers’ recommended spray paint. Paint only when the fire is OFF and cold. Always mask off the surrounding area to pre-
vent contamination with overspray. Ventilate the room during the use of the spray. DO NOT attempt to spray paint the coals/pebbles or
ceramics, or wash them in water.

Advise that the fire will emit a “newness” smell for a time after initial commissioning and that extra ventilation may be needed during this
time. Advise that the fire is fitted with a spillage safety device (O.D.S.). If the fire shuts down, this system may be in operation. If spillage is
suspected, SWITCH APPLIANCE OFF and call in the installer to investigate any problems.

SERVICING

Isolate the fire from the gas supply. Ensure that the fire is fully cold before attempting service. A suggested procedure for servicing is detailed
below.

1. Lay out the dust sheet and tools.
2. Carefully remove the ceramic components.
3. Remove the decorative front and frame.
4. Remove the two screws that retain the data/control plate. 
5. Disconnect the gas supply, and remove the two securing screws in the tray legs.
6. Remove the burner tray.
7. Remove convector box as described.

8

C

C

B

A

Fireplace Opening

Smoke Match

In Tube

Match

Crimp

Tube

Cross section of smoke match tube

Make a smoke match tube from 10mm diameter tube.
Seal off one end and crimp the tube to prevent the
smoke match from sliding down inside.

A . 2 5 m m
down from
top of open-
ing
B. 25mm in
from front of
opening.
C. Disregard
outer 50mm
either side of
f i r e p l a c e
opening

13.0

12.0

12.1

14.0

Содержание LULWORTH LPG

Страница 1: ...S F FIRE Focal Point Fires plc Christchurch Dorset BH23 2BT Tel 01202 499330 Fax 01202 499326 www focalpointfires co uk e mail sales focalpointfires co uk All i instructions m must b be h handed t to...

Страница 2: ...Lulworth LPG...

Страница 3: ...led by a competent person in accordance with Gas Safety Installation and Use Regulations 1998 It is strongly recommended that a CORGI registered engineer be used for this purpose Read all these instru...

Страница 4: ...iently y v ventilated s spac ce Consult a all i instruc ctions b before i installation a and u use o of t this a applianc ce This a applianc ce i is f free f from a any y a asbestos m material R Refra...

Страница 5: ...lled The flue must be connected to only one fireplace and the flue must not vent more than one appliance i e not shared with a gas back boiler There must be no opening in the flue apart from the one t...

Страница 6: ...liance must have a 50mm minimum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet must form a smooth path into the flue Any type of f...

Страница 7: ...iance can be fitted into a number of proprietary flue boxes provided that the minimum dimensions given in the diagram below are complied with Constructional N Note The frame of the fire any back panel...

Страница 8: ...nugly around the out side of the supply pipe and sleeving Note D DO NOT install or use the appliance without this seal in place If the hole is inadvertently opened reseal with an intact grommet Failur...

Страница 9: ...h fireplace openings Any sleeving should be sealed to the pipe at its ends The open end of the gas supply pipe should be temporarily sealed to prevent ingress of dust and dirt during installation CABL...

Страница 10: ...ough the spark click to the PILOT light position ensuring the pilot has lit If not return the knob clockwise and repeat When the pilot lights after the spark keep the knob depressed for approximately...

Страница 11: ...cating doors open Finally repeat with all doors open BRIEFING T THE C CUSTOMER All instructions must be handed to the user for safekeeping Show the customer how to light and control the fire After com...

Страница 12: ...e the tubing nut from the valve end of the pilot pipe and blow through to dis lodge any debris Clean the exterior of the pilot assembly with a soft brush and blow through the flame ports on the pilot...

Страница 13: ...f for a a t time a and t then c cuts o off Excessive room draught or flue pull rectify Loose or faulty thermocouple rectify ODS system in operation Firebox grommet seal not fitted rectify Lint in pil...

Страница 14: ...he elderly or infirm are concerned Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper may discolour if fitted too close to the fire See rele...

Страница 15: ...in force OPERATING I INSTRUCTIONS The pilot is visible through the left hand side of the matrix Rotate the coals pebbles for good viewing Push in and turn the control knob to the SPARK position and h...

Страница 16: ...s ensure that the fire is OFF and completely cold Debris that may form on the fuelbed should be periodically removed by a competent person Large deposits could indicate deterioration of the flue This...

Отзывы: