![Focal Point ALVOR Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/focal-point/alvor/alvor_installation-and-users-instructions_2313957006.webp)
Note: Ensure that the gas supply is isolated before commencing
installation of the appliance.
The fireplace opening and environment must be in compliance with specifica-
tions laid down in the appropriate sections of these instructions.
Remove the appliance from it’s carton as described previously and stand upon
a dust sheet or similar. Place the decorative frame, coals, ceramics and fixings
safely to one side. Remove the burner from the assembly by removing the
retaining screws.
Slide control models : Remove the slide control linkage connecting screw.
The tray is now free, and may be lifted away.
RADIANT PANELS :
The three radiant panels may now be fixed inside the firebox. Select the
plain or patterned side of each panel and insert as follows;
Lay the firebox on it’s back. Lay the tapered panel onto the rear face of the firebox.
The side panels should be fitted by inserting their front edges into the pre-fitted retaining brack-
ets on the front face of the firebox. Gently align the side panels with the side of the firebox as
shown in figure 3, over the top of the back panel already in place.
Make sure that the side panels are pushed
up
firmly to the roof of the firebox, and
back
firmly
to retain the tapered panel. Make small adjustments to line up the mortar lines if required. Secure
the side panels using the small ‘L’ shaped brackets and screws provided (figure 4). The screws
should locate into the pre-punched holes in the sides of the firebox.
SUPPLY PIPE ENTRY :
Knockout holes are provided in the rear and sides of the firebox for
use where concealed pipework is required. Where necessary, knock out the
appropriate hole with a sharp tap from a hammer, and fit the rubber grommet
supplied. A small incision can now be made in the rubber to slip snugly around
the outside of the pipe and sleeving.
Do not install or use the appliance
without the seal in place
. If a hole is inadvertently opened, reseal with an
intact grommet. Failure to fit the seal correctly will cause flue suction to act
upon the area under the burner, resulting in poor performance and intermittent
cutting out of the burner.
Slide controls models :
The control knob is supplied as a loose part. Insert
the control knob into the hole in the top of the slide control spindle (Figure
5). Secure the control knob in position using the M4 nyloc nut provided.
SPIGOT RESTRICTOR :
If installing the fire into a Class 1 or good Class
2 flue, simply bend up (stitch bend join) the spigot restrictor into position in
the flue outlet of the fire as shown in figure 6 and figure 7.
You MUST remove (or bend down fully) the spigot restrictor and
re-test if the appliance fails a spillage test during commissioning.
SEALING STRIPS :
Apply the self adhesive sealing strips to the back of
the fireframe as shown in figure 7 to give a continuous seal.
8.0 PREPARING THE APPLIANCE
GB IE
6
©
2010 Focal Point Fires plc.
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7