4.0 SITE REQUIREMENTS - CONTINUED

GB IE

4

All models : 

This appliance requires a natural draught flue system which may be one of the following;

225mm x 225mm (9in x 9in) brick or stone.

125mm (5in) minimum diameter lined brick or stone.

125mm (5in) minimum diameter twin wall flue conforming to BS 715.

Pre-cast block flue complying with BS 1289.

Any existing under grate draught device must be sealed off. The opening wall must be non-combustible.
The appliance requires a hearth with non-combustible surface of at least 12mm thick. The top surface must be at least 50mm above the
surrounding floor level, or be surrounded by a raised edge or fender 50mm high.

To enable the products of combustion to be cleared properly up the flue, the outlet at the back of the appliance must have a 50mm min-
imum clearance between it and the back wall of the opening or any other obstruction. The area immediately above the outlet must form
a smooth path into the flue.
Any type of fire surround used with this appliance must be adequately sealed to the wall and floor.
A combustible shelf may be fixed to the wall above the fire, providing that it complies with the dimensions given below.

A non-combustible shelf may be fitted to within 10mm of the top edge of the fireframe. Combustible materials, such as wood, may be
fitted to within 100mm (4in) of either side of the fireplace opening, providing the forward projection does not exceed 100mm (4in). Any
combustible side walls must be at least 500mm to the side of the radiant heat source. As with all heating appliances, any decorations,
soft furnishings, and wall coverings (i.e. flock, blown vinyl and embossed paper) positioned too close to the appliance may discolour or
scorch.

Radiant models have a mounting depth of 180mm. In accordance with BS 5871 part 2, minimum debris collection volumes are required
behind the installed appliance. These are shown below and as dimension ‘X’ in figure 1.

CLAY/CEMENT LINES OR BLOCK FLUE WHICH IS NEW, UNUSED, OR PREVIOUSLY ONLY USED WITH A GAS FIRE.

X Dimension = 20mm

UNLINED  FLUE OR CHIMNEY WHICH HAS BEEN PREVIOUSLY USED FOR A SOLID FUEL OR OIL BURNING APPLIANCE

X Dimension = 60mm

‘A’

. Opening height: 545mm min/575mm max. 

‘B’

. Opening width: 390mm min/440mm max. 

‘C’

. Mounting depth: 180mm.

‘D’

. Hearth must extend minimum of 150mm either

side of the  opening.

‘E’

. Hearth must extend minimum of 300mm in front

of the opening.

‘F’

. Non-combustible hearth must be a minimum of

50mm in height, or be surrounded by 50mm high

fender.

‘G’

. 470mm, this area must be flat and vertical to

ensure a good seal.

‘H’

. 585mm, this area must be flat and vertical to

ensure a good seal.

‘X’

. Debris collection space - See section 4.1.

Maximum depth of shelf                       Minimum distance from finished hearth

surface to underside of shelf

100mm

745mm 

150mm

845mm 

203mm

895mm

4.1 DEBRIS COLLECTION SPACE

‘A’

‘C’

‘B’

‘E’

‘F’

‘G’

‘H’

‘X’

‘D’

Figure 1

© 

2010 Focal Point Fires plc.

Содержание ALVOR

Страница 1: ...L CONTROL ONLY AVAILABLE WITH MANUAL OR SLIDE CONTROL FULL DEPTH INSET GAS FIRE Please note Except where otherwise stated all rights including copyright in the text images and layout of this booklet i...

Страница 2: ...y or infirm are concerned a suitable fireguard should be used Consult ALL instructions before installation and use of this appliance This appliance is free from any asbestos material Refractories and...

Страница 3: ...t vent more than one appliance i e not shared with a gas back boiler There must be no opening in the flue apart from the one that the appliance is installed into and the one venting the gases into the...

Страница 4: ...either side of the fireplace opening providing the forward projection does not exceed 100mm 4in Any combustible side walls must be at least 500mm to the side of the radiant heat source As with all he...

Страница 5: ...bscure the flue box outlet The firebox base of the flue box and hearth below may be drilled to allow plugs and screws to secure installation It is important that the sealing requirements of the appli...

Страница 6: ...provided figure 4 The screws should locate into the pre punched holes in the sides of the firebox SUPPLY PIPE ENTRY Knockout holes are provided in the rear and sides of the firebox for use where conc...

Страница 7: ...s during fixing When the opening is ready for installation of the fire the gas supply may be routed as per the examples shown in figure 8 IMPORTANT Wherever a concealed connection is made a rubber gro...

Страница 8: ...the inlet restrictor elbow from the inlet pipe Connect the previously installed gas supply to inlet restrictor elbow Place the burner unit into the firebox making sure that the rear lugs locate prope...

Страница 9: ...n To turn the fire OFF move the slide control knob upwards fully to the position marked O The spark gap shown in figure 16 between the spark electrode and the thermocouple should be 3 5 4 5mm to produ...

Страница 10: ...ustomer should be instructed on the safe use of the appliance and the need for regular servicing Frequency of serv ice depends on usage but MUST be carried out at least once annually Advise that clean...

Страница 11: ...e accu mulated The filter element should also be blown clean This component should not require replacement however if signs of deteriora tion are evident then a genuine spare part must be used If a la...

Страница 12: ...e an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit t...

Страница 13: ...here are no defects or obstructions that may prevent the flow of combustion products This appliance is fitted with a flue blockage safety device which will shut down the fire if abnormal flue conditio...

Страница 14: ...HIGH setting move the slide control knob upwards to the HIGH flame setting The fire can also be set to operate anywhere between HIGH and LOW by moving the control knob to an inter mediate position To...

Страница 15: ...rientated as desired to achieve a realistic effect Keep the spacing between the coals even and uniform The two coals at the ends of the row may be placed rearwards towards the back corners of the fuel...

Страница 16: ...now complete IMPORTANT The fire is designed to operate correctly with the pebbles supplied when assembled according to the instructions Never add to the sixteen pebbles or change them for a different...

Страница 17: ...0 of these instructions Slide control models only Ensure appliance is off and cool The battery is located underneath the ignition unit on the left hand side of the burner Insert 1 x PP3 9 volt battery...

Страница 18: ...e hope therefore you will understand we must retain the right to amend details and or specifications without prior notice 6 F861020 GB IE Note Gas SafeTM registered operatives are the only class of pe...

Отзывы: