Model: MU-JR-PSGN130-H50

2

 Product Overview

* Dilution rates and flow rates given are based on chemical with viscosity of water and factory air pressure settings.

Product requirements

Operating air pressure

50-80 psi (3.4-5.5 bar)

Liquid temperature range

40-100˚F (4.4-37˚C)

Chemical compatibility

Chemical products used with this equipment must be formulated for 

this type of application and compatible with unit materials and pump 

seals.  For more information on chemical compatibility, consult the 

manufacturer or SDS for your product or contact our customer service 

department.

MU50-PSGN130

Power type 

Electricity

Chemical pickup type

Draws from pre-mixed solution

Number of products unit can draw from One product
Suction line length/diameter

6 ft. (1.8 m) clear hose with 1/4 in. (6.4 mm) inside diameter

Discharge line length/diameter

50 ft. (15.2 m) twin-line tubing 1/4 in. (6.4 mm) outside diameter

Discharge wand/tip type

Polypropylene trigger handle for liquid output and polypropylene fog/

mist nozzle with Kynar tip 

Output distance

3-4.5 ft. (0.9-1.4 m)

Output volume

8.96 oz/min at 50 psi (3.4 bar) - static

Flow rate*

8.96 oz/min at 50 psi (3.4 bar) - static

Pump seals

Santoprene, Viton, or Kalrez

Droplet size

15 microns at 50 psi (3.4 bar)

Coverage area

1 liter of solution will cover approximately 1000 cubic feet

Nozzle type

Pneumatic fog nozzle

Number of nozzles

One

Product specifications

Содержание MU-JR-PSGN130-H50

Страница 1: ...ist Unit User Manual MU JR PSGN130 H50 READ ALL INSTRUCTIONS BEFORE USING OR SERVICING THIS EQUIPMENT KEEP THIS MANUAL IN A LOCATION THAT IS READILY AVAILABLE TO USERS AND SERVICE TECHNICIANS English...

Страница 2: ...10 Page 2 of 11 Model MU JR PSGN130 H50 Contents 1 Safety 3 2 Product Overview 5 Product Requirements 5 Product Specifications 5 Product components 6 3 Operation 7 4 Parts 9 5 Air Compressor Instructi...

Страница 3: ...ent may cause an unexpected release of the chemical solution and cause serious injury such as burns rashes eye damage throat or lung damage and death Always depressurize and clean the unit after each...

Страница 4: ...before the unit may result in diminished performance and damage to the unit Do not use an air lubricator before the unit Moisture in the air lines may damage the pump and diminish the units life The...

Страница 5: ...0 PSGN130 Power type Electricity Chemical pickup type Draws from pre mixed solution Number of products unit can draw from One product Suction line length diameter 6 ft 1 8 m clear hose with 1 4 in 6 4...

Страница 6: ...ir discharge hose 6 Air compressor handle and frame 7 Air gauge 8 Air tank 9 Electrical cord 10 Air inlet shut off valve 11 Suction hose 12 PSG N130 wand 13 Air discharge shut off valve Product compon...

Страница 7: ...e air compressor 4 Verify that the air shut off valve at the trigger gun is in the closed position and 5 Open the air inlet valve QFSOV14 to the control box 6 Point the discharge wand in a safe direct...

Страница 8: ...h OFF to shut off the air compressor 12 Unplug the air compressor 13 Open the air shut off valve at the trigger gun and squeeze the trigger handle to relieve any pressure remaining in the unit Once pr...

Страница 9: ...10 Page 9 of 11 Model MU JR PSGN130 H50 4 Parts FV2 H14C H14BU H14RU H14TRB 50 H14TRB 100 H14BU QF14P CV14QF S QFBH14 QF14PAF QFT14 ACLA5721 P56 P56K or P56V QFSOV14 PSG N130 PFN NZGRD QF1214 PSG12 PF...

Страница 10: ...rbs air fitting and exhaust barb P56K Pump with Kalrez seals includes hose barbs air fitting and exhaust barb P56V Pump with Viton seals includes hose barbs air fitting and exhaust barb PFN N130 Pneum...

Страница 11: ...Do not use an extension cord unless absolutely necessary It is better to use a long air hose to reach area where work is being performance If use of an extension cord can not be avoided refer to the...

Отзывы: