10
B 540-27-F + feed pump_7009077
US – 07-02-2019
3.2 Location and Mounting
WARNING
Danger of damage to property and personal injury
Improper installation of the unit presents a danger of personal damage and
damage to machines.
The equipment shall only be moved to the final installation place, with suitable
hoists..
The system should always be located in a frost-free room. Stationary system must always be mounted where
the surfaces are of solid quality, and when applicable the fastening must always be done with the delivered
bolts and raw plugs. Holes for wall brackets must be drilled according the dimensional drawing.
The booster should be connected to an adequate pipe system. This should correspond to distance from the
water supply, the maximum water flow and vertical distance from the boosting System.
3.3 Water Supply
NOTICE
Connection to water supply should always be done in according to local or
national standards.
If the legislation in your country requests safeguards for reverse current,
this must be provide for.
BEFORE
mounting the system, the piping must be flushed with water in order to remove possible parts or
dirt.
CAUTION
Damage to equipment caused by blockage
Any wastewater entering the machine may severely damage the equipment.
At the supply pipe to the main station a valve and filter must be installed. We
recommend using Original FOAMICO installations set.
CAUTION
Damage to equipment caused by blockage
Any wastewater entering the machine may severely damage the equipment.
Before the satellite a valve and filter must be installed. We recommend using
Original FOAMICO installations set.