Troubleshooting / Failures
5.6
Troubleshooting.
Fault
Cause
Action
No rinsing pressure.
Booster or main station not started.
Start booster/or main station.
Too many users on the same time.
Check maximum number of users.
The ball valve at the inlet of the system is
not opened.
Open the ball valve.
Unstable rinsing pressure.
Unoriginal rinsing nozzle with too high
water consumption is used.
Change to master rinsing nozzle – observe
technical data for model.
The system does not suck up any
detergent into the injector.
Operation handle is not in position”
foam”.
Turn into position” foam”.
Limiting nozzles is to small
The dosing must be adjusted. Check with
the description from the detergent
supplier. Change he nozzle.
Limiting nozzle is blocked by chemical
remains.
Change the limiting nozzle.
Injector system is blocked by chemical
remains.
Injector system and water nozzle in the
injector must be disassembled and
cleaned.
Leakages on the detergent inlet. Air is
drawn into the detergent line
Check the chemical inlet. Change the
suction hose.
Blocked suction filter at the end of the
suction hose.
Clean or change suction filter.
Empty chemical container.
Change to new chemical container.
Suction filter above fluid level in the
chemical container.
Lead the suction filter underneath the
fluid level.
No compressed air to the system.
Open the air inlet to the system.
The rinsing hose is” pounding”.
Chemical product mixed with water.
Exchange the chemical container.
The used chemistry is not a foam
product.
Change to a foam product.
Injector system is blocked by chemical
remains.
Injector system and water nozzle in the
injector must be disassembled and
cleaned.
Limiting nozzle is blocked by chemical
remains.
Change the limiting nozzle
Fault
Cause
Action
Low foam quality.
No compressed air to the system.
Open the air inlet to the system.
Wrong product.
Change to a foam product.
Unoriginal foam nozzle is installed.
Change to original 50/200 foam nozzle,
installed with white nozzle guard.
Insufficient air supply to the system.
Min. 150 l/min. and max. 200 l/min. at
4-6 bars is requested.
Air pressure not set correct.
Is adjusted on the air regulation valve to
be 4-6 bars.
Operation selector is not in the
position” foam”.
Turn it into the position” foam”.
Содержание 7001412
Страница 7: ...7 MSC 0106_NEXT_7001412 17_UK 22 08 2019 3 3 Model Overview Type 1 MS C 0106 1 Type 2 MS C 0106 2...
Страница 12: ...12 MSC 0106_NEXT_7001412 17_UK 22 08 2019 MS ULTRA NEXT 0106 2 XA...
Страница 13: ...13 MSC 0106_NEXT_7001412 17_UK 22 08 2019 MS ULTRA NEXT 0106...
Страница 27: ...27 MSC 0106_NEXT_7001412 17_UK 22 08 2019 8 Electrical diagram 8 1 Electrical diagram MS 0106 and MS 0106 EX...
Страница 28: ...28 MSC 0106_NEXT_7001412 17_UK 22 08 2019 8 1 1 Electrical diagram 240V AC 8 1 2 Electrical diagram 24 DC...
Страница 30: ...30 MSC 0106_NEXT_7001412 17_UK 22 08 2019 8 2 1 Electrical diagram 240V AC 8 2 2 Electrical diagram 24 V DC...