![FOAMICO 7001412 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/foamico/7001412/7001412_operation-manual_2313313011.webp)
11
MSC 0106_NEXT_7001412-17_UK
22-08-2019
5.4
Spray disinfection
.
1. Mount the disinfection nozzle in the coupling at the low pressure valve / gun (marked with yellow
protection)
2. set the handle
POS. D
fig. 5.1 in disinfection position
3. The system is now ready for sanitizing. Sanitize by open the low pressure valve / gun.
4. After sanitizing the system must be rinsed with clean water. Place the hose for disinfection in a container
with clean water. Open the low pressure valve/ gun for minimum 15 sec
5. ATTENTION! Set the handle
POS D
fig 5.1, back in rinse position
when Foam operation is ended.
6: ATTENTION! Before choosing another cleaning operation with another chemical, the system must be
flushed with clean water for at least 30 seconds. This is done by following the instructions in 5.2 “rinsing
operation”
5.5
Stop of operation
1. Make sure that the injectors have been rinsed with clean water
2. ATTENTION! When not used the mains station must be shut off. Turn the Handle
POS D
fig 5.1 into stop
position
. Close the valves at
POS. E
fig.5.1
3. Depressurize the hose by opening the low pressure valve /gun.
4. Disconnect the hose.
Содержание 7001412
Страница 7: ...7 MSC 0106_NEXT_7001412 17_UK 22 08 2019 3 3 Model Overview Type 1 MS C 0106 1 Type 2 MS C 0106 2...
Страница 12: ...12 MSC 0106_NEXT_7001412 17_UK 22 08 2019 MS ULTRA NEXT 0106 2 XA...
Страница 13: ...13 MSC 0106_NEXT_7001412 17_UK 22 08 2019 MS ULTRA NEXT 0106...
Страница 27: ...27 MSC 0106_NEXT_7001412 17_UK 22 08 2019 8 Electrical diagram 8 1 Electrical diagram MS 0106 and MS 0106 EX...
Страница 28: ...28 MSC 0106_NEXT_7001412 17_UK 22 08 2019 8 1 1 Electrical diagram 240V AC 8 1 2 Electrical diagram 24 DC...
Страница 30: ...30 MSC 0106_NEXT_7001412 17_UK 22 08 2019 8 2 1 Electrical diagram 240V AC 8 2 2 Electrical diagram 24 V DC...