* Dilution rates and flow rates given are based on chemical with viscosity of water and factory air pressure settings.
** Area covered and run time may vary based on humidity, air flow, and product used.

V20200501 

• 

Page 5 of 14 

Model: MU-AC-15N, MU-AC-15N-PSGN130

Product requirements

Liquid temperature range

40-100˚F (4.4-37˚C)

Electrical requirements

120 VAC at 60 Hz, 8.5 amps (GFCI protected outlet)

Operating voltage

120 VAC

Chemical compatibility

Chemical products used with this equipment must be formulated for 

this type of application and compatible with unit materials and pump 

seals.  For more information on chemical compatibility, consult the 

manufacturer or SDS for your product or contact our customer service 

department.

Power type 

Electricity

Chemical pickup type

Draws from pre-mixed solution

Number of products unit can draw from One product

Suction line length/diameter

3/8 in. (9.5 mm) inside diameter

Capacity

15 gallons (56.8 liters)

Discharge line length/diameter

25 ft. (7.6 m) coiled twin-line tubing with 1/4 in. (6.4 mm) outside diameter

Discharge wand/tip type

Handheld double-barrel misting wand with one nozzle or Polypropylene 

trigger handle with misting nozzle

Output distance

3-4.5 ft. (0.9-1.4 m)

Output volume

8.9 oz/min (263.2 ml/min) at 50 psi (3.4 bar)

Flow rate*

8.9 oz/min (263.2 ml/min) at 50 psi (3.4 bar)

Pump seals

Santoprene, Viton, or Kalrez

Run time from full tank**

Approx. 3.5 hours

Nozzle type

Pneumatic fog nozzle

Number of nozzles

1 nozzle

Droplet size

15 microns at 50 psi (3.4 bar)

Wheel type

Two 10 in. (25.4 cm) non-marking wheels
Two 5 in. (12.7 cm) casters with lock

Product specifications

Содержание MU-AC-15N

Страница 1: ...Unit User Manual MU AC 15N MU AC 15N PSGN130 READ ALL INSTRUCTIONS BEFORE USING OR SERVICING THIS EQUIPMENT KEEP THIS MANUAL IN A LOCATION THAT IS READILY AVAILABLE TO USERS AND SERVICE TECHNICIANS En...

Страница 2: ...Product Overview 5 Product Requirements 5 Product Specifications 5 Product Components 6 3 Assembly 8 4 Operation 9 5 Troubleshooting 11 6 Parts 13 Contents V20200501 Page 2 of 14 Model MU AC 15N MU AC...

Страница 3: ...T use a solution with a temperature above 100 F 37 77 C Operating the unit when damaged or leaking may result in exposure to chemical solutions serious injury or death Never use the unit if it is dama...

Страница 4: ...the motor Always use a 3 wire extension cord that has a 3 blade grounding plug and is no more than 25 ft long and at least 14 gauge Operating the air compressor motor with excessive or insufficient el...

Страница 5: ...r customer service department Power type Electricity Chemical pickup type Draws from pre mixed solution Number of products unit can draw from One product Suction line length diameter 3 8 in 9 5 mm ins...

Страница 6: ...ck fit check valve 6 Suction line valve 7 In line strainer Product components Before you begin get to know the MU AC 15N and MU AC 15N PSGN130 components that you will need to use adjust or assemble V...

Страница 7: ...n line valve 14 MGA RAC N130 wand 15 Drain plug 16 Air compressor bracket 17 120V air compressor 1HP 18 Tank 19 Air supply line 20 25 ft coiled tubing V20200501 Page 7 of 14 Model MU AC 15N MU AC 15N...

Страница 8: ...lign the holes on the compressor bracket with the holes on the front tank sides 4 Fasten the screws into the bracket 5 Attach the in blue air hose from that back of the unit to the air compressor usin...

Страница 9: ...discharge wand in a safe direction and open the air shut off valve at the trigger gun Then squeeze the trigger handle to begin misting Note Both discharge valves should be completely open while mistin...

Страница 10: ...e any pressure remaining in the unit Once pressure is relieved release the trigger handle and close the air shut off valve at the trigger gun On model MU AC 15N Press the red and blue trigger buttons...

Страница 11: ...gauge and adjust the air regulator if needed The air regulator is factory set at 50 psi Operating pressure is 50 psi Check the air compressor AC120V 1HP CAT to confirm sufficient air pressure is bein...

Страница 12: ...oise Low voltage supply to the motor Check that the main voltage corresponds to specifications An extension cord that is too thin or too long can cause a voltage drop and cause the motor to overheat A...

Страница 13: ...1HP CAT AG100 AP25 BVB14 CST5SS L CST5SS CT25 CV14QF S QFSOV14 DFP7 DP A H14BU H14B F H38B F P56 P56K P56V PSG N130 R25 QF1214 PSG12 TANK 15N C TANK 15NC CATBRKT W15 STR38 IL HHPB3414 PVCV34FM HBSSEL...

Страница 14: ...e barb 1 4 mpt x 3 8 barb elbow HHPB3414 Hex head poly bushing 3 4 mpt x 1 4 fpt MGA RAC N130 Misting gun assembly rac gun PFN N130 P56 Pump with santoprene seals includes hose barbs air fitting and e...

Отзывы: