FOAM-iT MU-AC-15N Скачать руководство пользователя страница 3

1

 

Safety

PEOPLE OR OBJECTS CAN BE HURT OR DAMAGED IF THIS UNIT IS NOT USED CORRECTLY!

Failure to read all the instructions before operating the unit may result in personal injury or death from 

the improper use of the chemical solution. Anyone handling, operating or using the unit must read, 

and understand, the instructions in the manual. The buyer assumes all responsibility for safety and 

proper use in accordance with the instructions.

Using, or servicing, the unit without proper protective clothing, gloves, and 

eye wear may result in serious injury such as burns, rashes, eye, throat 

or lung damage and death. Always wear protective clothing, gloves, and 

eye wear when using, or servicing, the unit. Protect eyes, skin, and lungs 

against drifting spray.

Chemical solutions may pose a health risk and death if they contact the skin or eyes, are inhaled 

or swallowed. Always read, and follow, all chemical safety precautions and handling instructions 

provided by the chemical manufacturer and the Safety Data Sheet (SDS) associated with the chemical 

solution being used before using the unit.
Pressure within the equipment may cause an unexpected release of the chemical solution and 

cause serious injury such as burns, rashes, eye damage, throat or lung damage and death. Always 

depressurize and clean the unit after each use. Never leave the unit unattended while pressurized.
Using the unit with fluid temperatures above 100°F (37.77°C) may result in scalding, burns, serious 

injury or death. DO NOT use a solution with a temperature above 100°F (37.77°C).
Operating the unit when damaged or leaking may result in exposure to chemical solutions, serious 

injury or death. Never use the unit if it is damaged or leaking.
Never point the discharge wand at yourself, another person, or any object you do not want covered  

in chemical.
Using incoming air pressure exceeding 100 psi (7 bar) may result in pressure buildup, explosion, 

serious injury or death. DO NOT exceed 100 psi (7 bar) incoming air pressure when operating the unit.
Use of hydrocarbons and flammable products may result in explosions, fire and serious injury or 

death. Never use hydrocarbons or flammable products with the unit.
Mixing an alkaline with an acid may result in a chemical reaction. Overheating of the mixture may 

cause it to splatter caustic compounds or release hazardous fumes, gas and vapors. Always flush  

the unit with fresh water for five (5) minutes when switching from an alkaline to an acid or an acid to  

an alkaline.
Touching damaged electrical cords (i.e.: bare wires, bare receptacles) may result in electrical shock, 

serious injury or death. Always inspect the electrical cords and extension cords for damage before 

connecting the unit to the power supply. DO NOT touch a damaged electrical cord, or extension cord, 

that is connected to the power supply. 
Operating the air compressor in wet weather or in wet conditions may result in electrical shock, 

serious injury or death. Always place the unit (air compressor) in an area away from the misting 

direction. DO NOT touch the air compressor, electrical or extension cords if your hands or feet  

are wet.

V20200501 

• 

Page 3 of 14 

Model: MU-AC-15N, MU-AC-15N-PSGN130

WARNING

!

Содержание MU-AC-15N

Страница 1: ...Unit User Manual MU AC 15N MU AC 15N PSGN130 READ ALL INSTRUCTIONS BEFORE USING OR SERVICING THIS EQUIPMENT KEEP THIS MANUAL IN A LOCATION THAT IS READILY AVAILABLE TO USERS AND SERVICE TECHNICIANS En...

Страница 2: ...Product Overview 5 Product Requirements 5 Product Specifications 5 Product Components 6 3 Assembly 8 4 Operation 9 5 Troubleshooting 11 6 Parts 13 Contents V20200501 Page 2 of 14 Model MU AC 15N MU AC...

Страница 3: ...T use a solution with a temperature above 100 F 37 77 C Operating the unit when damaged or leaking may result in exposure to chemical solutions serious injury or death Never use the unit if it is dama...

Страница 4: ...the motor Always use a 3 wire extension cord that has a 3 blade grounding plug and is no more than 25 ft long and at least 14 gauge Operating the air compressor motor with excessive or insufficient el...

Страница 5: ...r customer service department Power type Electricity Chemical pickup type Draws from pre mixed solution Number of products unit can draw from One product Suction line length diameter 3 8 in 9 5 mm ins...

Страница 6: ...ck fit check valve 6 Suction line valve 7 In line strainer Product components Before you begin get to know the MU AC 15N and MU AC 15N PSGN130 components that you will need to use adjust or assemble V...

Страница 7: ...n line valve 14 MGA RAC N130 wand 15 Drain plug 16 Air compressor bracket 17 120V air compressor 1HP 18 Tank 19 Air supply line 20 25 ft coiled tubing V20200501 Page 7 of 14 Model MU AC 15N MU AC 15N...

Страница 8: ...lign the holes on the compressor bracket with the holes on the front tank sides 4 Fasten the screws into the bracket 5 Attach the in blue air hose from that back of the unit to the air compressor usin...

Страница 9: ...discharge wand in a safe direction and open the air shut off valve at the trigger gun Then squeeze the trigger handle to begin misting Note Both discharge valves should be completely open while mistin...

Страница 10: ...e any pressure remaining in the unit Once pressure is relieved release the trigger handle and close the air shut off valve at the trigger gun On model MU AC 15N Press the red and blue trigger buttons...

Страница 11: ...gauge and adjust the air regulator if needed The air regulator is factory set at 50 psi Operating pressure is 50 psi Check the air compressor AC120V 1HP CAT to confirm sufficient air pressure is bein...

Страница 12: ...oise Low voltage supply to the motor Check that the main voltage corresponds to specifications An extension cord that is too thin or too long can cause a voltage drop and cause the motor to overheat A...

Страница 13: ...1HP CAT AG100 AP25 BVB14 CST5SS L CST5SS CT25 CV14QF S QFSOV14 DFP7 DP A H14BU H14B F H38B F P56 P56K P56V PSG N130 R25 QF1214 PSG12 TANK 15N C TANK 15NC CATBRKT W15 STR38 IL HHPB3414 PVCV34FM HBSSEL...

Страница 14: ...e barb 1 4 mpt x 3 8 barb elbow HHPB3414 Hex head poly bushing 3 4 mpt x 1 4 fpt MGA RAC N130 Misting gun assembly rac gun PFN N130 P56 Pump with santoprene seals includes hose barbs air fitting and e...

Отзывы: