background image

                                          FMUSER INTERNATIONAL GROUP INC. 

广州市汉婷生物技术开发有限公司

 

 

12

 / 

39

 

 

4 Network Setting

4.1 IP Address

4.3 Gateway

4.2 Subnet Mask

4.4 MAC Address

4.5 SCR IP Address

SCR IP Address 2

SCR IP Address 3

SCR IP Address 4

SCR IP Address 1

5 Saving Configuration

6 Loading configuration

6.1 Load Saved CFG

6.2 Factory Default

7 Version(SNMP)

 SW 0.11    HW 2.1

8 Language

English/

中文

3 Output Setting 

3.1 Output 1

3.4 Output 4

2 Input Setting

2.1 Port  1

Sat Freq Set

LNB Freq Set

Symbol Rate

2.8 Port  6

LNB Voltage

1.6 22 KHz Switch

Prog Parse

Attenuation

NIT Insertion

Output Stream

Trans Stream

Out Address

Output Carrier

Out IP Enable

Srv Address

Srv Mask

Srv Gateway

Srv Mac Add

Out Port

(Same content with 

Output 1

)

(Same content with 

Port 1

)

2.8 Port  7

Prog Parse

2.10 Port  7

Prog Parse

 

Содержание FUTV4443A-10

Страница 1: ...FMUSER INTERNATIONAL GROUP INC FUTV4443A 10 4 in 1 Mux Scrambling QAM User s Manual NMS Version 3 3 8 SW 0 12 HW 2 1...

Страница 2: ...el 6 Chapter 3 Installation Guide 6 3 1 Acquisition check 6 3 2 Installation Preparation 6 Chapter 4 Operation 10 4 1 LCD Menu Tree 11 4 2 Main Interface 13 Chapter 5 SNMS Setting 21 5 1 Installation...

Страница 3: ...low cost This is very adapting to newly generation CATV broadcasting system 1 2 Features l Support 6 DVB S2 tuner 4 ASI input optional l Fully support DVB C EN300 429 and ITU T J 83A B C l Fully suppo...

Страница 4: ...ymbol Rate 2 5Msps 4 66Msps 5 0Msps 8 0Msps 1ksps stepping Constellation 16 32 64 128 256QAM FEC RS 204 188 RF Output Interface F typed output port for 4 carriers 75 impedance RF Range 48 1000 MHz 1kH...

Страница 5: ...ea All the indicators will light on when the 4 in 1 Mux Scrambling QAM works at current state 2 1 Front Panel 1 LCD Display 2 Indicator Area POWER Power Indicator Alarm Alarming Indicator ECMG1 2 3 4...

Страница 6: ...package of the device it is necessary to check items according to packing list Normally it should include the following items l FUTV4443A 4 IN 1 Mux Scrambling QAM 1pc l User s Manual 1pc l Tuner wir...

Страница 7: ...should be 1 2 1 5m and the distance to wall should be no less than 0 8m Machine hall floor Electric Isolation Dust Free Volume receptivity of ground anti static material 1 107 1 1010 Grounding current...

Страница 8: ...uency impedance and the grounding wire must be as thick and short as possible 3 The 2 terminals of grounding wire must make sure for well electric conducting and process for antirust 4 It is prohibite...

Страница 9: ...ring the same ground with other devices When the device adopts united way the grounding resistance should be less than 1 FCaution Before connecting power cord to 4 in 1 Mux Scrambling QAM user should...

Страница 10: ...nction Description MENU Canceling presently entered value resuming previous Setting Return to previous menu ENTER Activating the parameters which need modifications or confirming the change after modi...

Страница 11: ...FMUSER INTERNATIONAL GROUP INC 11 39 4 1 LCD Menu Tree...

Страница 12: ...Factory Default 7 Version SNMP SW 0 11 HW 2 1 8 Language English 3 Output Setting 3 1 Output 1 3 4 Output 4 2 Input Setting 2 1 Port 1 Sat Freq Set LNB Freq Set Symbol Rate 2 8 Port 6 LNB Voltage 1 6...

Страница 13: ...ng By pressing LOCK key to enter the main menu the LCD will display the main menu as the following pages By pressing UP DOWN LEFT DOWN key to choose the specified menu item then pressing ENTER to ente...

Страница 14: ...he LCD window when Constellation been entered J 83A DVB C contains 16QAM 32QAM 64QAM 128QAM and 256QAM J 83B contains 64QAM 256QAM J 83C contains 64QAM 256QAM Note The more advanced QAM constellation...

Страница 15: ...s as 6 875Msps symbol rate Constellation qam_bits bit symb Symb_rate Msps Max_input_bitrate Mbps 16 4 6 875 25 343 32 5 31 679 64 6 38 015 128 7 44 350 256 8 50 686 4 2 2 4 Symbol rate After entering...

Страница 16: ...elect Input setting in the main interface and then press ENETR to view the inputting ports The display show as below The setting principle is the same for 2 1 to 2 6 turner input port Hereby we just t...

Страница 17: ...gram Parse setting principle is the same as tuner input 4 2 4 Output Setting User can select Output setting in the main interface and then press ENETR to set the outputting parameters The display show...

Страница 18: ...Carrier 3 1 2 Attenuation 3 1 3 NIT Insertion 3 1 4 Output Stream 3 1 1 Output Carrier On Off 3 1 2 Attenuation 00 0 dB 3 1 3 NIT Insertion On Off 3 1 5 Trans Stream 3 1 6 Out Address 3 1 7 Out Port...

Страница 19: ...cording to the factory setting and it s unique Under the following submenus there are parameters which can be set manually user can press Up Down to choose this item Enter and Left Right to set the pa...

Страница 20: ...er chooses 6 1 to load saved configuration the display shows as below When user chooses 6 2 to restore the device into factory configuration the display will automatically return to the main menu as b...

Страница 21: ...he specified directory X XX is version number Y represents language For example the version number of network management software 4 01E exe is 4 01 English version or place different versions of netwo...

Страница 22: ...tically If both of them are correct the main interface will appear Both of the default user name and password are admin 5 2 2 Main Interface User can create a device node tree in the left column by ad...

Страница 23: ...y to pop up the short cut menu in device tree or in the left blank column then the Add Freq Point dialog box popes up by choosing Add Main Freq Point The device will confirm the given frequency while...

Страница 24: ...d Equipment dialog box popes up by user s choosing Add Equipment 5 2 5 Edit Equipment Interface User should follow the steps as below l Inputting the device IP Address l Inputting the device Port Numb...

Страница 25: ...the NMS PC IP address should be 192 168 2 X 1 X 255 submask is 255 255 255 0 5 2 6 Delete Equipment User can choose the equipment to be deleted in the left column and then click the delete item in th...

Страница 26: ...rd disk Similarly user can choose to click the button on the toolbar to popup the read file dialog box to read the stored binary file and set the device s parameters according to the loaded binary fil...

Страница 27: ...ting in the main interface 5 3 1 Mux Scrambler Setting In this field users can set and get the device inputting parameters 5 3 1 1 Mux In this box all 10 inputting ports 6 tuner input and 4 ASI input...

Страница 28: ...bottom left corner Programs refresh input out User can select the program to be multiplexd and click the arrow to add it to the right box or user can delete the programs which have been multiplexed f...

Страница 29: ...shown above User can select the item to be modified and input new information in the corresponding box below To prosper the modification pls do click the Modify botton at right and Confirm botton at l...

Страница 30: ...nt Otherwise it will cause IP conflict and the device will not work normally Crypto Period This field means the scrambling crypto period of the current outputting channels After the specified crypto p...

Страница 31: ...current configuration and click the Cancel to quit the current operation 5 3 1 3 Transparent Transport Pass User can decide to bypass the inputting PID as needed in this interface This interface can b...

Страница 32: ...FMUSER INTERNATIONAL GROUP INC 32 39 5 3 1 4 Parameters User can set the output parameters in this interface the display shows as below...

Страница 33: ...R INTERNATIONAL GROUP INC 33 39 5 3 1 5 NIT NIT Network Information Table NIT table is a very important table for describing the network and TS Users can set the parameters of the output NIT table as...

Страница 34: ...TS The private descriptor includes two parts One is descriptor tag and the other is descriptor information The descriptor tag is an 8 bit field which identifies each descriptor 5 4 Out Setting User c...

Страница 35: ...64QAM 256QAM optional Symbol Rate range 2 5Msps 4 66Msps 5 0Msps 8 0Msps 1ksps stepping Bandwidth 6M optional Out gain attenuation ranges 25dBm 6dBm 0 5dB stepping 5 5 Real time Monitor In this interf...

Страница 36: ...FMUSER INTERNATIONAL GROUP INC 36 39 Prearrange Update time 5 7 Parameters User can set the parameters in this interface the display shows as below...

Страница 37: ...FMUSER INTERNATIONAL GROUP INC 37 39 User can edit and insert PSI SI by clicking It will pop up the following interface...

Страница 38: ...C l Making sure good ventilation for the heat sink on the rear panel and other heat sink bores if necessary l Checking the input AC voltage within the power supply working range and the connection is...

Страница 39: ...FMUSER INTERNATIONAL GROUP INC 39 39 Chapter 7 Packing List l FUTV4443A 4 IN 1 Mux Scrambling QAM 1pc l User s Manual 1pc l Tuner wire 5pcs l ASI wire 4pcs l Grounding wire 1pc...

Отзывы: