Operating Instruction Digital Grease Meter

Maintenance

7. 

The grease meter is designed for a utilization requiring low maintenance efforts, only. See the following 
details:

Exchange of empty batteries.

Exchange of batteries

7.1 

The meter will be supplied with two 1,5V alcaline batteries.

    Attention!

 
Please dispose the empty batteries according to local regulation, only.

For changing of batteries proceed as follows (Reference to the position of the spare parts list):

 Remove the locking screw (pos. 17).

 Remove the empty batteries.

Replace the old batteries by the new ones. Take care that the position of the positive pole corresponds 

the illustration of the explosion drawing.
Tighten the locking screw carefully. Take care for a correct re-positioning of the O-ring (pos. 16) and of 

the spring (pos. 15).
The meter re-starts automatically. The normal operation can be started again. 

After the change of the batteries all data for resetable dispensed volumes, for total and for partial volumes 
will be displayed as before.
The meter will utilize the same calibration factor after the change of the batteries or after an electrical 
power blackout as before. The is no re-calibration reqired.

Cleaning

7.2 

The metering chamber of the grease meter can be cleaned even if the meter is connected to a grease gun 
or installed in a grease distribution line.

    Attention!

Take care a every time that the meter is not perssurized prior to any cleaning process.

Die Reinigung der Kammer erfolgt folgendermaßen (Verweis auf die Position der Ersatzteilliste):

For cleaning of the meter proceed as follows ((Reference to the position of the spare parts list):

Remove the four screws of the lower cover (pos. 13).

Remove the cover (pos. 12) and the O-ring (pos.10)

Take out the oval gear wheels (pos. 9).

Proceed with the cleaning. We recommend the use of a suitable brush or of a pointed tool, i.e. a small 

screw driver.
Clean carefully so the gear wheels will not be damaged. 

For the re-assembly follow the a.m. advises vice versa.

    Attention!

Take care for a correct re-assembly of the gear wheels (see explosion drwaing).

Содержание 18115

Страница 1: ...Operating Instruction Digital Grease Meter Art no 18115 82 319 A801...

Страница 2: ...2 G Operating Instruction Digital Grease Meter...

Страница 3: ..._______________________________________6 Switch off 5 4 ___________________________________________________________________________6 Main display 5 5 __________________________________________________...

Страница 4: ...ism The impulses will be converted based on a pre set factor into the effective volume and indicated on the display The factor is pre set by the manufacturer on an average volume which can be individu...

Страница 5: ...se saftey instructions will not be observed Attention Potential light or medium personal injuries or damages Moreover an additional advise offering general recommendations for the operation of the pro...

Страница 6: ...a long time Press the right pushbutton longer than 1 sec TOTAL Press the left pushbutton labelled with TOTAL for a short time TOTAL press for a long time Press the left pushbutton longer than 1 sec RE...

Страница 7: ...to the last digit on the right TOTAL long stores the preset value as nominal value and calculates the K factor showing it for 1 second before changing to the main display again Change of the preset K...

Страница 8: ...nsed volumes for total and for partial volumes will be displayed as before The meter will utilize the same calibration factor after the change of the batteries or after an electrical power blackout as...

Страница 9: ...d and manufactured with respect to the highest quality standards Should a quality problem appear despite of all qualtity precautions please contact our customer s service FMT Swiss AG Tel 49 9462 17 2...

Страница 10: ...10 G Operating Instruction Digital Grease Meter Explosion drawing 11 1 3 4 2 5 6 8 10 11 12 13 14 15 16 17 19 18 7 9 20...

Страница 11: ...2 Cylinder bolt 3m 6x16 82 315 8 2 Magnets 03 003 9 2 Oval gearwheel 82 314 10 1 O ring 24 x2 87 224 11 2 Cylinder bolt 4m6x10 82 316 12 1 Cover 82 311 13 4 Cylinder head screw M6 x12 82 317 14 2 Batt...

Страница 12: ...FMT Swiss AG Fluid Management Technologies Swiss AG Gewerbestra e 6 6330 Cham Schweiz Tel 41 41 712 05 37 Fax 41 41 720 26 21 info fmtag ch www fmtag ch...

Отзывы: