Operating instructions for turbine flow meter
The flow chart below shows the schematics of the display modes the LCD display may go through.
In this mode, the user may press RESET and thus change from the USER to the FACTORY FACTOR .
In order to confirm your choice, shortly press TOTAL while the display shows either USER or FACT.
After re-start, the meter will use the new calibration factor you just confirmed.
Tip
When you confirm restoration of the Factory K Factor, the old user factor will be deleted from
memory.