7
Operating Instructions - PREMAxx Diesel Pump
GB
DANGER
Risk of injury and material damage from explosive vapors!
■
■
Never use the pump to deliver fatty substances or explosive fluids such
as petrol or other fluids with similar flashpoints!
■
■
Since the motor and the switch are not explosion-protected, the pump must
not be operated in an explosion risk area.
■
■
Pumping caustic or other hazardous chemical or biological substances is
forbidden.
■
■
Do NOT use the pump in an explosion-risk area. No open fire, no smoking.
Use the pump exclusively for delivering diesel fuels or heating oils.
2.4. Risks when handling the PREMAxx diesel pump
DANGER
Risk of injury and material damage because of improper installation,
electric current or contaminated media!
Never work on a pump that is running!
■
■
Mount or remove attachments and accessories only when the pump is
switched off from all sources of energy.
■
■
Before the pump is put into operation, this one must be tightly screwed to
the dispensing container.
■
■
The pump is only allowed to be operated, if it is screwed to the dispensing
container and thus cannot carry out any uncontrolled movements.
■
■
The pump is only allowed to be operated if the dispensing container, to
which the pump is connected, stands on a firm and level surface.
■
■
For your own safety, disconnect the pump in addition from the power supply.
■
■
Never leave the pump unattended.
■
■
Check to ensure that the pump does not work against the closed nozzle
Do not pump contaminated fluids
■
■
Take special care to ensure that there are no contaminants in the fluid to be
pumped.
■
■
Install a strainer on the suction pipe.
Damaged attachments and accessories can lead to personal injury and
material damage
■
■
Attachments and accessories must be checked for wear, splits or other
damage throughout their period of use.
■
■
Damaged accessories and attachments must be replaced immediately.
■
■
With reference to the period of use, please note the details in ZH 1/A45.4.2
or DIN 20066 Part 5.3.2
Escaping liquids can cause environmental harm
Comply with the stipulations of the German Water Resources Act (WHG) and
of the Plant Regulations of the German federal states (VawS).