13

Operating instructions - digital oval gear meter and pulse meter  

US

 

5.  The display will show all the segments again. Only then follows  
       the phase where all segments are switched off. Finally, there  
      will be a display showing the total that has been reset (RESET  
      TOTAL).

7.2    Output of liquid with display of current flow rate (Flow Rate Mode)

It is possible to output a liquid and have the following displays available at the same time:

 Partial volumes having been output

Current flow rate (Flow Rate) in [unit of partial volume per min.], as shown below.

This is how you get into this mode:

 Wait until the meter is in default standby mode (i.e. the display shows only the total volume).

Press TOTAL shortly.

Start output operation.

The display of the current flow rate will be updated every 0.7 secs. For that reason the display may ‚flutter‘ 

somewhat with low flow rates. However, the higher the flow rate, the more stable the display will be.

NOTE

The current flow rate will be shown in the unit set for the partial volume register. 

That means if partial and total volume have been set to different units (as shown in 

the example below) you must bear in mind that the flow rate shown is in the unit 

set for partial volumes. In the example shown, the flow rate is in QTS./min.

The word GAL next to the flow rate refers to the register of the (resettable and NON-resettable) total 
volumes which will be displayed again as soon as you leave the  ‚current flow rate‘ display mode.

In order to go back to the default standby mode, press the TOTAL button again.

Accidental pressing of the RESET or TOTAL button does not have any effect in this state.

NOTE

RESET TOTAL and absolute total (TOTAL) are not shown in this mode.  

However, the values nevertheless go up. You can check after fluid discharge. 

Wait for the default standby mode and press TOTAL shortly.

7.2.1  Resetting partial volumes

In order to reset the partial volume register, you must first complete the output of liquid. Wait until the 

display shows a flow rate of 0.0 (see fig.) and then press RESET shortly.

Содержание 23 190

Страница 1: ...OPERATING INSTRUCTIONS AND SAFETY NOTES NUMERIxx3 oval gear meter 2 100 l min Pulse meter IPG 82 363 006 A803 US...

Страница 2: ...not be duplicated or distributed neither in full or in part utilized for the purpose of competition or passed on made availabe to third parties FMT Swiss AG Fluid Management Technologies Swiss AG Gewe...

Страница 3: ...ration Normal Mode __________________________________11 7 1 1 Resetting partial volumes_____________________________________________________________12 7 1 2 Resetting the resettable total volume RESET...

Страница 4: ...ety rules legal provisions as well as all other binding rules regarding occupational safety accident prevention and environmental protection Wear appropriate protective clothing in accordance with the...

Страница 5: ...to perform The dash denotes lists a The arrow identifies cross references If cross references to other chapters are required within the text the expression is shortened for reasons of clarity Example...

Страница 6: ...on or other undesirable alterations of water properties occur According to 19i WHG the operator of such an installation is obliged to monitor permanently the compliance with the aforementioned require...

Страница 7: ...registers and different types of display modes showing information to the user only when it is actually needed with the operation function going on at the moment Key 1 Register of partial volume 5 dig...

Страница 8: ...ration mode Pressed together the two buttons call up the configuration mode where you select the unit of measurement 3 1 3 Measuring chamber The measuring chamber is located in the centre of the meter...

Страница 9: ...42 Pre set flow direction horizontal horizontal horizontal Permitted liquid temperature max F 104 104 104 Permitted ambient temperature F 14 140 14 140 14 140 Measuring tolerance 0 5 0 5 0 5 Nominal p...

Страница 10: ...stor mOhm 300 300 Material housing stainless steel stainless steel stainless steel External dimensions LxWxH inch 3 94 x 3 94 x 2 56 3 94 x 3 94 x 2 56 3 94 x 3 94 x 2 56 Weight lb 2 31 2 31 2 31 Tab...

Страница 11: ...tal volumes RESET TOTAL and TOTAL share the same window and the same digits of the LCD display For that reason the two numbers cannot be viewed at the same time The oval gear meter has been programmed...

Страница 12: ...on all the segments one after the other and then switch them all off again When the reset is complete the display will first show the partial volume having been reset and then RESET TOTAL After a cou...

Страница 13: ...ll be NOTE The current flow rate will be shown in the unit set for the partial volume register That means if partial and total volume have been set to different units as shown in the example below you...

Страница 14: ...on procedure 8 2 Why calibrate The oval gear meter comes to you with a calibration factor pre set at the factory that will guarantee the most precise measurements under most operating conditions If ca...

Страница 15: ...ecessary Go to default standby mode Press the TOTAL button The display shows the valid calibration factor Two situations are possible a User never changed the calibration factor and or user restored t...

Страница 16: ...s digitalovalgearmeterandpulsemeter Standby Standby Standby RESET long RESET short TOTAL long TOTAL short Time OL 1 Key NOTE When you confirm restoration of the Factory K Factor the old user factor wi...

Страница 17: ...nstead turn the spigot on and off and fill the vessel in small batches but make sure the flow rate remains unchanged When you are finished be sure to wait a few minutes and let air bubbles escape that...

Страница 18: ...efore you do this For calibration you must correct the count indicated by the partial volume register ex 9 800 entering the actual value i e the volume of the cal vessel An arrow at the bottom left of...

Страница 19: ...phase but the word TOTAL will remain unchanged If you carry out this action right after point 5 the new USER K FACTOR will be equal to the FACTORY K FACTOR It will be ignored therefore 9 NO OPERATION...

Страница 20: ...is true if the value indicated is greater than the actual amount positive error Operation Display configuration 1 NONE Meter is in default standby mode not counting 2 PRESS RESET SEVERAL SECS Meter ch...

Страница 21: ...new value set will be used as the new valid K Factor and will remain even after replacement of batteries 9 NO OPERATION The meter stores the new K Factor for operation and is now ready for serious op...

Страница 22: ...o time Exchange the batteries when discharged Clean the measuring chamber This may be necessary from time to time depending on the specific liquid s being measured and or when foreign matter gets into...

Страница 23: ...e the meter after exchange of batteries 10 2 Cleaning The measuring chamber of the oval gear meter can be cleaned only after disconnecting the meter from the pipeline or spigot The inlet and outlet mu...

Страница 24: ...error reading data usually when exchanging batteries Control circuit board automa tically switches on and off to restore proper operation 12 Repairs service This oval gear meter has been designed and...

Страница 25: ...ation of volumes of various media featuring different viscosities such as diesel heating oil and DEF Complies with all relevant provisions of the following Directive EC Directives 2014 30 EU EMC Direc...

Страница 26: ...Exploded view and mounting dimensions pulse meter and digital oval gear meter without display Fig 15 2 Mounting dimensions pulse meter and digital oval gear meter without display in mm Fig 15 1 Explo...

Страница 27: ...20 5 4 Countersunk screw M 5x12 6 2 Disc magnet 5x3 mm 7 2 Oval gear 8 2 Fillister head screw M 3x6 9 1 Sensor carrier board 10 1 Intermediate cover 11 2 Straight pin 8x36 12 1 O ring NBR 70 68 x 1 5...

Страница 28: ...r 16 Exploded view and mounting dimensions pulse meter and digital oval gear meter with display Fig 16 1 Exploded view pulse meter and digital oval gear meter with display Fig 16 2 Mounting dimensions...

Страница 29: ...magnet 5x3 mm 7 2 Oval gear 8 2 Fillister head screw M 3x6 9 1 Sensor carrier board 10 1 Intermediate cover 11 2 Straight pin 8x36 12 1 O ring NBR 70 68 x 1 5 13 1 Housing lower part 14 1 Seal 97 6 x...

Страница 30: ...30 US Operatinginstructions digitalovalgearmeterandpulsemeter...

Страница 31: ...31 Operatinginstructions digitalovalgearmeterandpulsemeter US...

Страница 32: ...FMT Swiss AG Fluid Management Technologies Swiss AG Gewerbestra e 6 6330 Cham Schweiz Tel 41 41 712 05 37 Fax 41 41 720 26 21 info fmtag com www fmtag com...

Отзывы: