background image

Operating Manual AZS01B and AZS04B

 

 

 

14.08.2018

 

 

12 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

 

FMS Force Measuring Sys-
tems AG

 

Aspstrasse 6 
8154 Oberglatt (Switzerland) 
Tel. 0041 1 852 80 80 
Fax 0041 1 850 60 06 
[email protected] 
www.fms-technology.com

 

FMS USA, Inc. 
2155 Stonington Avenue 
Suite 119 
Hoffman Estates,, IL 60169 
(USA) 
Tel. +1 847 519 4400 
Fax +1 847 519 4401 
fmsusa@fms-
technology.com

 

FMS (UK)

 

Aspstrasse 6 
8154 Oberglatt (Switzer-
land) 
Tel. +44 (0)1767 221 303 
[email protected]

 

FMS (Italy) 
Aspstrasse 6 
8154 Oberglatt (Switzerland) 
Tel. +39 02 39487035 
[email protected] 

 

 

Содержание AZS01B BlueFLash

Страница 1: ...17 NS This operation manual is also available in English Please contact your local FMS representative Diese Bedienungsanleitung ist auch in Englisch erhältlich Bitte kontaktieren Sie Ihren nächstgelegene FMS Vertretung by FMS Force Measuring Systems AG CH 8154 Oberglatt Alle Rechte vorbehalten ...

Страница 2: ...tion Conditions 3 2 Functional Description 4 3 Dimensions 5 4 Assembly Preparations 6 4 1 Assembly Conditions 6 5 Installation 7 5 1 Mounting the Sensor 7 5 2 Wiring 7 6 Operation 8 6 1 Right or Left Hand Position of the Sensor 8 6 2 Adjustment of the Sensors 9 7 Trouble Shooting 10 8 Technical Data 11 ...

Страница 3: ...of a fault to the equipment 1 1 Description Conditions a Danger of health injury or loss of life Danger This symbol refers to high risk for persons to get health injury or loss life It has to be followed strictly b Risk of damage of machines Caution This symbol refers to information that if ignored could cause heavy mechanical damage This warning has to be followed absolutely c Note for proper fun...

Страница 4: ...s the material edge with high resolu tion Signal processing is microcontroller based using sophisticated software algo rithm The short 1ms cycle time allows the BlueFlash handle very fast material speeds The used ultra linear high resolution material edge mapping system pro vides to BlueFlash clear advantages compared to ultrasonic sensors They are fac tory set and don t need any calibration Two s...

Страница 5: ...8 2018 5 3 Dimensions Fig 1 AZS01B Fig 1a AZS04B Sensor AZS01B AZS04B mm in mm in A Throat width 30 1 18 90 3 54 B Throat depth 25 0 98 80 3 15 C Sensor height 85 3 35 145 5 71 D Sensor length 70 2 76 125 4 92 F Hole distance 30 1 18 30 1 18 ...

Страница 6: ...health and safety requirements of opera tors working with it the following conditions for the installations must be met Caution The Material Sensors may not be stressed over the specification limits neither during assembly nor operation Caution The attachment points for the Sensors on the machine frame must be properly designed The used mounting screws must be of the right size Caution For correct...

Страница 7: ...djustment etc It must be ordered separately 5 2 Wiring Fig 2 Sensor Connector in front view with its pin assignment The table lists the wire colour corresponding to the signal names Pin_Assignment ai Electrical Connections If the sensor is used with a built in web guide controller in the steering frame FMS webMASTER series the sensor is connected with a cable 4x0 14mm2 of the re spective length Fi...

Страница 8: ...Sensor Definition of Left and Right Seen in direction of the running web Fig 3 Position of the sensors according to the web BKS309 1 Web entry side 2 Web exit side 3 Direction of moving web 4 Material sensor s 5 Left hand sensor axis 6 Left hand web edge 7 Right hand sensor axis 8 Left hand web edge ...

Страница 9: ... the web in the sensor 3 The positioning marks provide a quick and precise alignment of the sensor to the reference edge 4 Align sensor axis to the web edge 5 Tighten the fixation nut with the sensor in the new position 6 The sensor will be properly positioned if the web edge runs through the sensor axis covering half of the transmitter or receiver ref to Fig 4 7 The LED in the connector socket wi...

Страница 10: ...ct socket left plug to left socket etc With mesh mate rial BKS guides web edge out of the sensor area Frequency of the sensor signal causes malfunc tion of the web guiding controller Update firmware of BKS309 con troller to 3 42 Steering frame does not move No signal sensor not correctly connected Connect sensor correctly according to screw terminal arrangement and installation guide of web guide ...

Страница 11: ...AZS01B M8 AZS04B M8 Detection range 16 mm 0 63 Resolution 0 06 mm 0 002 Measuring rate 2 ms Linearity 0 05 10 to 50 C 14 to 122 F Output Signal to 10 VDC Power Supply 24VDC 18 to 30VDC Connector M8 connector 4 pole Temperature Range 10 to 50 C 14 to 122 F Protection Class IP 60 ...

Страница 12: ... fms technology com www fms technology com FMS USA Inc 2155 Stonington Avenue Suite 119 Hoffman Estates IL 60169 USA Tel 1 847 519 4400 Fax 1 847 519 4401 fmsusa fms technology com FMS UK Aspstrasse 6 8154 Oberglatt Switzer land Tel 44 0 1767 221 303 fmsuk fms technology com FMS Italy Aspstrasse 6 8154 Oberglatt Switzerland Tel 39 02 39487035 fmsit fms technology com ...

Отзывы: