background image

www.fmiproducts.com

122274-01G

3

  WARNING:  Any  change  to 

this firebox or its controls can 

be dangerous.

 WARNING: Do not allow fans 

to blow directly into the firebox. 

Avoid any drafts that alter burner 

flame patterns. Ceiling fans can 

create  drafts  that  alter  burner 

flame  patterns. Altered  burner 

patterns can cause sooting.

 WARNING: Do not use a blow

-

er insert, heat exchanger insert 

or other accessory not approved 

for use with this firebox.

Due  to  high  temperatures,  the 

appliance should be located out 

of traffic and away from furniture 

and draperies.

Do not place clothing or other 

flammable material on or near 

the appliance. Never place any 

objects  in  the  firebox  or  on 

logs.

Firebox  front  and  screen  be

-

comes  very  hot  when  running 

firebox. Keep children and adults 

away from hot surfaces to avoid 

burns or clothing ignition. Fire

-

box  will  remain  hot  for  a  time 

after shutdown. Allow surfaces 

to cool before touching.

Carefully supervise young chil

-

dren when they are in the room 

with firebox.

Keep the fireplace area clear and 

free from combustible materials, 

gasoline, and other flammable 

vapors and liquids.

SAFETY

Continued

You must operate this fireplace 

with  the  provided  fireplace 

screen  and  hood  in  place. 

Make  sure  these  parts  are  in 

place  and  screens  are  closed 

before  running  installed  gas 

log  heater.  Replace  hood  with 

FMI PRODUCTS, LLC model 

109511-01  50",  109511-02  42", 

or 109511-03 36" only. This hood 

has been designed to keep the 

operation of your fireplace safe 

and efficient.

1.  Do not use this firebox as a wood burning 

fireplace. Use only decorative unvented 

room heaters (log sets).

2.  Do not add extra logs or ornaments such as 

pine cones, vermiculite or rock wool. Using 

these added items can cause sooting.

3.  Use only the provided hood. See 

Parts

page 30.

4.  Vent-free gas log heaters installed in these  

fireboxes require fresh air ventilation to 

run properly. See 

Air for Combustion and 

Ventilation

, page 8.

5.  Do not run vent-free heaters installed in 

these fireboxes
• where flammable liquids or vapors are 

used or stored

• under dusty conditions

6.  Do not use this firebox to cook food or 

burn paper or other objects.

7.  Turn unit off and let cool before servicing. 

Only  a  qualified  service  person  should 

service and repair firebox.

8.  Operating vent-free heaters installed in 

these fireboxes above elevations of 4,500 

feet could cause pilot outage.

9.  Do  not  use  the  firebox  if  it  has  been 

under water.

10. Before using furniture polish, wax, carpet 

cleaner or similar products, turn heater 

off. If heated, the vapors from these prod-

ucts may create a white powder residue 

within  burner  box  or  on  adjacent  walls 

and furniture.

11. Provide adequate clearances around air 

openings.

Содержание VUM50

Страница 1: ...al switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future referenc...

Страница 2: ... fireplace size requirement DO NOT INSTALL THE APPLIANCE IN THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM DIMEN SIONS REQUIRED FOR THE INSTALLATION WARNING FOR USE ONLY WITH A LISTED GAS FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO EXCEED 40 000 BTU H DO NOT BUILD A WOOD FIRE SAFETY This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohib...

Страница 3: ...creens are closed before running installed gas log heater Replace hood with FMI PRODUCTS LLC model 109511 01 50 109511 02 42 or109511 0336 only Thishood has been designed to keep the operation of your fireplace safe and efficient 1 Do not use this firebox as a wood burning fireplace Use only decorative unvented room heaters log sets 2 Do not add extra logs or ornaments such as pine cones vermiculi...

Страница 4: ...CATING FIREBOX PLANNING Plan where you will install the firebox This will save time and money later when you install the firebox Before installation consider the following 1 Where firebox will be located Allow for wall and ceiling clearances see Installa tion Clearances page 11 2 Everything needed to complete installation 3 These models CANNOT be installed in a bedroom unless maximum Btu rating of...

Страница 5: ...274 01G 5 PRODUCT SPECIFICATIONS 36 MODELS Figure 1 36 Models V UM36 and V QM36 Series 30 1 2 29 30 11 1 8 54 1 2 7 7 8 7 36 45 1 8 35 16 97 16 50 365 16 7 3 8 111 8 36 HEARTH 1 5 16 19 13 16 Ref 34 3 4 22 18 3 8 3 3 4 4 7 8 ...

Страница 6: ... 6 PRODUCT SPECIFICATIONS Continued 42 MODELS Figure 2 42 Models V UM42 and V QM42 Series 4 7 8 54 1 2 7 7 8 7 36 5 16 50 42 51 1 8 32 3 8 3 3 4 30 5 16 8 3 4 13 3 5 16 9 7 16 30 11 1 8 23 13 16 Ref 1 5 16 40 3 4 25 22 1 2 42 HEARTH ...

Страница 7: ...G 7 PRODUCT SPECIFICATIONS Continued 50 MODELS Figure 3 50 Models V UM50 AND V QM50 Series 365 16 50 8 3 4 13 35 16 97 16 23 13 16 Ref 1 5 16 33 40 3 4 22 1 2 50 HEARTH 59 1 8 50 7 7 8 7 30 54 1 2 11 1 8 32 3 8 3 3 4 38 5 16 4 7 8 ...

Страница 8: ...et to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms WARNING This heater shall notbeinstalledinaroomorspace unlesstherequiredvolumeofin door combustion air is provided by the method described in the National Fuel Gas Code ANSI Z223 1 NFPA54 theIn...

Страница 9: ...ecause the actual Btu Hr used is more than the maximum Btu Hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventilation grills between rooms See Ventilation Air From Inside Building B Vent room directly to the outdoo...

Страница 10: ...TION Log heaters installed in this firebox create warmaircurrents Thesecurrents move heat to wall surfaces next to firebox Installing firebox next tovinylorclothwallcoveringsor operating firebox where impuri ties suchas butnotlimitedto to bacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls or cause odors INSTALLATION NOTICE The firebox identif...

Страница 11: ...ntel above built in fire box you must meet the minimum allowable clearance between mantel shelf and top of firebox opening shown in Figure 7 These are the minimum allowable mantel clearances for a safe installation Use larger clearances wherever possible to minimize the heating of objects and materials placed on the mantel CAUTION Do not allow the vent freegaslogheatertotouch or extend beyond the ...

Страница 12: ...ly insert firebox into rough opening 5 Attach firebox to wall studs using nails or wood screws through holes in nailing flange see Figure 10 6 Install and properly test gas log heater Follow installation instructions included with the vent free gas log heater that is being installed IMPORTANT When finishing your firebox combustible materials such as wall board gypsum board sheet rock drywall plywo...

Страница 13: ... your home The firebox and cabinet mantel can be installed directly on the floor Mantels may be avail able from your retailer or custom built for your home 1 Assemble cabinet mantel as instructed 2 Install gas piping to firebox location See Installing Gas Line page 14 You may have to cut an access hole in the floor or wall to run gas line to firebox Make sure to locate access hole so cabinet mante...

Страница 14: ...ht Face Slot Figure 14 Slots for Firebrick Walls 3 Secure the firebrick wall using 2 of the retainers provided The bracket will slip underneath the metal lip on the top of the wall and screw into the inner dome of the fireplace Figure 15 Figure 15 Installing Side Walls Retaining Bracket Leading Bricks Right Wall 4 Install the rear firebrick wall last Place the wall face side down on the hearth wit...

Страница 15: ...void spilling Place a wet towel over the bucket making sure it is directly on the surface of grout mixture This will keep the mixture moist and it will not dry out before use 5 Grout all joints where two firebrick walls come together 6 Using a trowel remove excess grout mix ture by moving trowel in the direction of the joint Grout mixture in the joint should now be flush with brick surface If not ...

Страница 16: ...ection see Figure 20 Note Secure incoming gas line to wood framing to provide rigidity for threaded end 4 Repack insulation around gas line and into sleeve opening Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired Figure 19 Gas Line Access Side Firebrick Finished Side Brick with A...

Страница 17: ...t or has a broken component please do not return it to the store Call FMI PRODUCTS LLC at 1 866 328 4537 to answer questions and replace parts under warranty Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty When calling or writing please have your model and serial numbers of your fireplace ready Model and serial number information ...

Страница 18: ...www fmiproducts com 122274 01G 18 PARTS MODELS V UM SERIES AND V QM SERIES 11 10 11 13 14 15 16 14 4 3 22 20 21 20 1 19 5 14 15 16 13 12 11 9 7 6 8 17 2 12 18 ...

Страница 19: ... Top 1 20 109457 03 Screen 36 2 109457 02 Screen 42 2 109457 01 Screen 50 2 117556 03 Screen 36 Stainless 2 117556 02 Screen 42 Stainless 2 117556 01 Screen 50 Stainless 2 21 20806 Screen Rod 36 2 110146 03 Screen Rod 42 2 110146 02 Screen Rod 50 2 117568 03 Screen Rod 36 Stainless 2 117568 02 Screen Rod 42 Stainless 2 117568 01 Screen Rod 50 Stainless 2 22 109511 01 Hood 50 1 109511 02 Hood 42 1 ...

Страница 20: ...www fmiproducts com 122274 01G 20 PARTS MODELS MODELS V UM SERIES AND V QM SERIES Picture may vary from actual 1 6 4 8 7 3 2 5 7 7 7 8 9 ...

Страница 21: ... 125439 01 Right Stacked 50 Red 1 125451 01 Right Herringbone 50 Red 1 6 124214 01 Left Stacked 36 Red 1 124226 01 Left Herringbone 36 Red 1 125417 01 Left Stacked 42 Red 1 125429 01 Left Herringbone 42 Red 1 124441 01 Left Stacked 50 Red 1 125453 01 Left Herringbone 50 Red 1 7 124134 01 Side Retainer 36 UM Series 4 124134 02 Side Retainer 42 50 UM Series 4 124134 04 Side Retainer 36 Stainless QM ...

Страница 22: ... Rear Herringbone 50 Ivory 1 5 124212 02 Right Stacked 36 Ivory 1 124224 02 Right Herringbone 36 Ivory 1 125415 02 Right Stacked 42 Ivory 1 125427 02 Right Herringbone 42 Ivory 1 125439 02 Right Stacked 50 Ivory 1 125451 02 Right Herringbone 50 Ivory 1 6 124214 02 Left Stacked 36 Ivory 1 124226 02 Left Herringbone 36 Ivory 1 125417 02 Left Stacked 42 Ivory 1 125429 02 Left Herringbone 42 Ivory 1 1...

Страница 23: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________...

Страница 24: ...is product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material labor and incidental costs associated with warranty repairs unless expressly covered by this warranty are not reimbursable under this warranty and are the responsibility of the owner Excluded ...

Отзывы: