Figure 14 - Pipe Connection

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

(V)3612ST

See-Through 

Fireplace

52 

3

/

4

"

48-12DM

48-12TM

Flue Pipe

46 

5

/

8

"

36-12DM

48-12TM

Flue Pipe

34 

5

/

8

"

24-12DM

48-12TM

Flue Pipe

22 

5

/

8

"

18-12DM

48-12TM

Flue Pipe

16 

5

/

8

"

12-12DM

48-12TM

Flue Pipe

10 

5

/

8

"

STL-12D

Chase Style 

Termination

1" to 12"

RLT-12D

Round Top 

Termination

7"

Hemmed 

End

12 

3

/

8

Stainless 

Inner Pipe

15" Galvanized 

Outer Pipe

PIPE INSTALLATION

The pipe sections must be assembled inde-

pendently as the chimney is installed. When 

connecting chimney directly to the fireplace, 

the inner flue pipe section must be installed first 

with the lanced side up. The outer pipe section 

can then be installed over the flue pipe section 

with the hemmed end up. Press down on each 

pipe section until the lances securely engage 

the hem on the fireplace starter. The wire will 

assure the proper spacing between the inner 

and outer pipe sections.

Continue to assemble chimney sections as 

outlined  above,  making  sure  that  both  the 

inner and outer pipe sections are locked to-

gether. When installing double wall snap-lock 

chimney together, it is important to assure the 

joint between the chimney sections is locked. 

Check by pulling chimney upward after lock-

ing. The chimney will not come apart if prop-

erly locked. It is not necessary to add screws 

to keep the chimney together (exception, see 

Figure 17, page 8).

 WARNING: The opening in the 

collar around the chimney at the 

top  of  the  fireplace  must  not  be 

obstructed. Never use blown insula-

tion to fill the chimney enclosure.

Figure 13 - Outside Air Kit Installation

Secure to Collars with 

Duct Tape or Screws

Air Inlet 

Location 

Must Allow 

For Bushes 

or Snow

Vent Hood 

Required for 

Wall Installation

Air Inlet 

Termination

Vented Crawl Space

(Check Local Codes 

Before Installing in a 

Vented Crawl Space)

CHIMNEY PIPE

The  FMI  PRODUCTS,  LLC  chimney  is  a 

snap-lock, double-wall pipe. It consists of a 

stainless steel inner flue pipe(s), a galvanized 

outer pipe and a wire spacer.
Each section of pipe comes in lengths of 12", 

18"  36"  and  48". The  actual  lineal  gain  for 

each is measured after each section is fully 

connected. Lineal gain is the actual measur-

able length of a part after two or more parts 

are connected. 

VenTing insTallaTion

Continued

USING ELBOW OFFSETS AND 

SUPPORTS

Chimney weight above offset rests on return 

elbow. Straps must be securely nailed to raf-

ters or joists (see Figure 15, page 8).

To  achieve  desired  offset,  you  may  install 

combinations of 12", 18", 36" and 48" length 

of  double  wall  pipe  (see  offset  chart  and 

Figure 16, page 8).

The  chimney  support  section  is  a  4"  strap 

and 12" length of pipe. A chimney support is 

required every 30 feet above fireplace after a 

straight chimney run or above a return elbow 

after a straight chimney run (see Figure 17, 

page 8). This support is designed to relieve 

the extra weight load on fireplace and elbows 

when high chimneys are installed.

Содержание (V)PN36-A

Страница 1: ...ved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard This wood burning fireplace complies with UL127 CAN ULS S610 M87 standard as a FACTORY BUILT APPLIANCE FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to deter mine the need to obtain a per...

Страница 2: ...FMI PROD UCTS LLC fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Although grounding may not be required by code in your area it must be electrically grounded in accordance with lo cal codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 This fireplace is intended for installation in ac cord...

Страница 3: ...lways leave glass doors fully opened or fully closed when operating fireplace WARNING Children and adults should be alerted to the hazardsofhighsurfacetempera tures and to stay away to avoid burns or clothing ignition Young children should be carefully su pervised when in the same room as fireplace Figure 1 V PN36 A Dimensions Nailing Flanges 21 19 12 10 1 4 40 12 3 7 11 1 4 36 1 2 37 1 2 22 5 8 6...

Страница 4: ... may be ideal for a new addition on an existing finished wall Minimum clearance to combustibles Back and sides of fireplace 1 2 min Adjacent wall 12 min Chimney outer pipe surfaces 2 min Bottom of fireplace to floor 0 min WARNING Do not block required air spaces with insu lation or any other material Do notobstructeffectiveopeningof fireplace with any type of facing material Combustible material m...

Страница 5: ...ugh flanges located on sides of the fireplace see Figure 8 Fireplace Installation Continued 1 2 MIN OVERLAP 1 2 MIN Figure 7 Ember Protectors Figure 8 Nailing Flanges Nailing Flanges Prepared Framing Nails or Screws 1 2 Minimum to Combustibles Hearth Extension A hearth extension projecting a minimum of 16 in front of and a minimum of 8 beyond each side of the fireplace opening is required to prote...

Страница 6: ...ing of the fireplace due to the nature of it s location Outside combustion air is accessed through and exterior wall or a vented crawl space CAUTION Air inlet ducts must not terminate in attic space The maximum height for the air vent can not exceed 3 feet below the flue gas outlet of the termination For further details on installation of outside air kit please refer to instructions included with ...

Страница 7: ...imney together exception see Figure 17 page 8 WARNING The opening in the collar around the chimney at the top of the fireplace must not be obstructed Neveruseblowninsula tion to fill the chimney enclosure Figure 13 Outside Air Kit Installation Secure to Collars with Duct Tape or Screws Air Inlet Location Must Allow For Bushes or Snow Vent Hood Required for Wall Installation Air Inlet Termination V...

Страница 8: ...FS 10 Firestop spacers are required at each point where the chimney penetrates a floor or ceiling joist space Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials When penetrating a floor or ceiling at an angle use firestop spacer number 30FS 10 see Re placement and Accessory Parts page 15 When the pipe passes through a framed open ing...

Страница 9: ...uter pipe of chimney with screws if screws do not penetrate inner flue pipe Figure 22 Maximum Chimney Height Storm Collar Flashing Firestop Spacer RLT 12D RLT 12D STL 12D Minimum Maximum Chimney Height The minimum height of the chimney mea sured from the base of the fireplace to the flue gas outlet end of pipe is 16 feet for a straight run 16 feet minimum for a run with 1 elbow set and 25 feet min...

Страница 10: ...erproof Caulk Storm Collar Flashing Flashing Installation Determine flashing to be used with roof open ing chart Slide flashing over pipe until base is flat against roof Replace as many shingles as needed to cover exposed area and flashing base Secure in position by nailing through shingles see Figure 24 DO NOT NAIL THROUGH FLASHING CONE Storm Collar Installation Place storm collar over pipe and s...

Страница 11: ...tile or other noncom bustible materials may overlap the front face provided they do not obstruct essential open ings like louvered slots or any other opening When overlapping with a noncombustible facing material use only noncombustible mortar or adhesive Installing fireplace facing Any noncombustible material may be used for facing glass tile brick etc as long as proper clearances are adhered to ...

Страница 12: ...automatic shutoff device and must comply with the Standard for Decora tive Gas Appliances for Installation in Vented Fireplace ANSI Z21 60 ONLY UNVENTED GAS LOG SETS WHICH HAVE BEEN FOUND TO COMPLY WITH THE STANDARD FOR UNVENTED ROOM HEATERS ANSI Z21 11 2 ARE TO BE INSTALLED IN THIS FIREPLACE Use only a 1 2 black iron pipe and appropri ate fittings 1 Remove knockout indentation on refrac tory or f...

Страница 13: ... chimney cleaner Creosote will ignite if heavily heated WARNING When using a decorative vented gas log the damper must be removed or permanently locked in the fully open position and the glass doors must be in the fully open position Note An appropriate FMI PRODUCTS LLC hood see Replacement and Accessory Parts page 15 must be installed when using an unvented gas log set Operation and Maintenance G...

Страница 14: ...calling please have your model and serial numbers of your heater ready You can also visit web site at www fmiproducts com damper Mechanism The damper control lever is located inside the fire chamber see Figure 32 Make sure lever is cool before handling Pull down to close and push up to open Damper must be open when lighting a fire Not doing so will cause smoke spillage into the room When fireplace...

Страница 15: ...Double Wall Pipe support assembly 12S 12DM Also available in triple wall Outside Air Kit AK4 Vent Plaster Collar Vent Hood Connector Duct 4 x 3 Storm Collar SC2 1 Firestop Spacer FS 10 for Straight Pipe 30FS 10 for 30 Angled Run Flashing V6F 10DM 0 to 6 12 Pitch V12F 10DM 6 12 to 12 12 Pitch Round Top Termination RLT 12D Econo Top Termination STL 12D Bi Fold Glass Doors DG368ST Brushed Brass DBP36...

Страница 16: ...115607 01 Rev D 09 09 2701 S Harbor Blvd Santa Ana CA 92704 1 866 328 4537 www fmiproducts com ...

Отзывы: