www.fmiproducts.com
117437-01F
25
LOGS
• If you remove logs for cleaning, refer to
Installing Logs and Glowing Embers
, page
19, to properly replace logs.
• Use a vacuum cleaner to remove any
carbon buildup on logs.
• Replace log(s) if broken. See
Replacement
Parts,
page 31.
• Replace ember material periodically as
needed. See
Replacement Parts
, page 31.
VENTING SYSTEM
Conduct annual inspection of the venting
system following these guidelines:
1. Check areas of venting system that are
exposed to the weather corrosion (rust
CLEANING AND MAINTENANCE
Continued
spots or streaks and in extreme cases,
holes). Have these items replaced im
-
mediately by a qualified service person.
2. Remove the vent cap and shine a flashlight
into vent. Remove any foreign material.
3. Check for evidence of excessive con
-
densation. Continuous condensation can
cause corrosion of caps, pipes and fittings
and can be caused by having excessive
lateral runs, too many elbows or exterior
portions of the system being exposed to
cold weather.
4. Inspect joints to verify that no pipe sec
-
tion or fitting has been distributed and
loosened. Check mechanical supports
such as wall straps for rigidity.
SPECIFICATIONS
(V)CB36N
• Maximum Input Rating: 18,000 Btu/hr
• Gas Type: Natural
• Orifice Size (Main Burner): #45 DMS
(0.082")
• Ignition: Millivolt
• Manifold Pressure: 3.5" w.c. (0.87 kPa)
• Min. Inlet Supply Pressure: 5.5" w.c. (1.1 kPa)
(V)CB36P
• Maximum Input Rating: 18,000 Btu/hr
• Gas Type: Propane/LP
• Orifice Size (Main Burner): #55 DMS
(0.052")
• Ignition: Millivolt
• Manifold Pressure: 10" w.c. (2.5 kPa)
• Min. Inlet Supply Pressure: 11" w.c. (2.7 kPa)
(V)CB36NE
• Maximum Input Rating: 18,000 Btu/hr
• Gas Type: Natural
• Orifice Size (Main Burner): #45 DMS
(0.082")
• Ignition: Electronic
• Manifold Pressure: 3.5" w.c. (0.87 kPa)
• Min. Inlet Supply Pressure: 5.5" w.c. (1.1 kPa)
(V)CB36PE
• Maximum Input Rating: 18,000 Btu/hr
• Gas Type: Propane/LP
• Orifice Size (Main Burner): #55 DMS
(0.052")
• Ignition: Electronic
• Manifold Pressure: 10" w.c. (2.5 kPa)
• Min. Inlet Supply Pressure: 11" w.c. (2.7 kPa)
ALL MODELS
• Fireplace Dimension HxWxD (Actual size of firebox measurements do not include nailing
flanges or standoffs): 35.75" x 36.25" x 14.75" (90.8 x 92.1 x 37.5 cm)
• Carton Dimension HxWxD: 36.75" x 38" x 16.25" (93.3 x 96.5 x 41.3 cm)
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• fireplace will not produce specified heat
• for propane/LP units, propane/LP gas sup
-
ply may be low
You may feel your gas pressure is too low. If
so, contact your local natural or propane/LP
gas supplier.
TECHNICAL SERVICES
You may have further questions about
installation, operation, or troubleshooting.
If so, contact FMI PRODUCTS, LLC at
1-866-328-4537. When calling please have
your model and serial numbers of your
fireplace ready.
You can also visit FMI PRODUCTS, LLC’s web
site at
www.fmiproducts.com
.