En-2

  1-888-514-1663  |  

WWW.OUTLANDLIVING.COM

LP SAFETY:

a.   Do not store a spare LP-gas cylinder under or  

near this appliance. 

b.  Never fill the cylinder beyond 80 percent full. 
c.   If the information in “(a)” and “(b)” is not followed exactly, a 

fire causing death or serious injury may occur.

Do not use this appliance under overhead combustible surfaces.

MINIMUM CLEARANCES:

•  Bottom: Non-Combustible Surface
•  Top: 80 inches
•  Sides: 36 inches
•   For Installation on (or over) non-combustible floors only

Input:  58,000 Btu/h (17 kW) and manifold pressure:  

11 in wc (2.74 kPa) 

Min. gas supply for input adj. 11 in wc (2.74 kPa)  
Max. gas supply: 
11 in wc (2.74 kPa) 
Injector Size* 2.32mm
* Injector size marked clearly on the gas valve orifice.
Type of Gas: Propane (LP)

This appliance shall be used only outdoors in a well-ventilated 
space and shall not be used in a building, garage or any other 
enclosed area. 

The gas supply must be turned off at the LP-gas supply cylinder 
when this appliance is not in use.

Indoor storage of this appliance is permissible only if the cylinder 
is disconnected and removed from the appliance. 

Cylinders must be stored outdoors in a well-ventilated area out of 
the reach of children. 

Disconnected cylinders must have threaded valve plugs tightly 
installed and must not be stored in a building, garage or any other 
enclosed area. 

The gas pressure regulator provided with this appliance must be 
used and must be the same model as supplied with the unit. 

The cylinder supply system must be arranged for vapor 
withdrawal. 

Cylinders used with this unit must have a collar to protect the 
cylinder valve. 

An approved LP-Cylinder stabilizer, such as the stabilizer ring 
included, must be used when the appliance is in use.

Replacement parts and a list of such parts are available from FMI 
Brands Inc. through the contact information provided on the last 
page of this Manual.

 

 WARNING:

Please ensure that all adults and children which use or are 
near a unit in use are aware of the hazard of high-surface 
temperatures present on the unit during use and should use 
caution and stay away to avoid burns or clothing ignition. 

Carefully supervise young children in the area of this 
appliance. Clothing or other flammable materials should 
not be hung from the appliance or placed on or near the 
appliance. Any guard or other protective device removed for 
servicing the appliance must be replaced prior to operating 
the appliance. 

Installation and repair should be done by a qualified 
service person. The appliance should be inspected before 
use and at least annually by a qualified service person. 
More frequent cleaning may be required as necessary. It is 
imperative that control compartment, burners and circulating 
air passageways of the appliance be kept clean. 

 

 WARNING:

Improper installation, adjustment, alteration, service or 
maintenance can cause injury or property damage. Read 
the installation, operating and maintenance instructions 
thoroughly before installing or servicing this equipment.

 WARNING:

If the information in this manual is not followed exactly, 
a fire or explosion may result causing property damage, 
personal injury or loss of life.

INSTALLER: Leave this manual with the appliance. 
CONSUMER: Retain this manual for future reference.

Содержание Outland Firebowl 823

Страница 1: ...venue Surrey B C Canada V3Z 3V7 Toll Free 1 888 514 1663 Fax 1 888 797 9931 Outland Firebowl is a registered trademark of FMI Brands Inc The OUTLAND Flame mark is a registered trademark of FMI Brands...

Страница 2: ...area call your gas supplier or fire department Failure to follow these instructions could result in fire or explosion which could cause property damage personal injury or death WARNING Do not store o...

Страница 3: ...inders used with this unit must have a collar to protect the cylinder valve An approved LP Cylinder stabilizer such as the stabilizer ring included must be used when the appliance is in use Replacemen...

Страница 4: ...ave total free area of not less than 1 2 in2 per lb 7 1 cm2 per kg of stored fuel capacity If ventilation openings at floor level area are in the side wall there shall be at least two openings The bot...

Страница 5: ...s in place prior to each use Insects will build nests in the tube if they can get in and this can cause a back flame event Always clear all valve and gas orifices of any foreign debris including spide...

Страница 6: ...ce in the gas regulator For more information about the CSA excess flow safety device see STEP 8 What is an Excess Flow Safety Valve EFV STEP 5 Leak Test all connections See section labeled Leak Test S...

Страница 7: ...e STEP 3 Allow unit to cool for at least five 5 minutes before relighting SECTION 4 EXTINGUISHING THE APPLIANCE WARNING The rocks are HOT WARNING Don t burn yourself Do not touch or handle the firebow...

Страница 8: ...ny gas control which has been under water Do not leave this appliance in the rain Your non toxic natural lava rocks will form cracks and change colour under normal operating conditions This does not a...

Отзывы: