www.fmiproducts.com
125795-01B
18
INSTALLATION
Continued
CAUTION: After installa-
tion and periodically thereafter,
check to ensure that no flame
comes in contact with any log.
With heater set to Hi, check to
see if flames contact any log. If
so, reposition logs according to
log installation instructions in
this manual. Flames contacting
logs will create soot.
LOG PLACEMENT
It is very important to install these logs exactly
as instructed. Do not modify logs. Only use
logs supplied with heater or for MF models,
as identified for use with the heater as shown
in Figure 27.
Note: Each log includes an identifying number
cast in the log. Look at each log when plac-
ing them on the burner system to be certain
it is correct.
Note:
For additional information, go to
www.fmiproducts.com
and click on the
technical Support tab for access to log
placement videos.
Figure 27 - MF Series Burner System-
Log Compatibility Chart
INSTALLING LOGS, EMBERS AND
LAVA ROCK
WARNING: Failure to position
the parts in accordance with these
diagrams or failure to use only
parts specifically approved with
this heater may result in property
damage or personal injury.
MF SERIES BURNER SYSTEM-LOG
COMPATIBILITY CHART
1. Find the right front log (LMF36-SC and
VFGT24 inch models: D-061 or LMF42-
SC and VFGT30 inch models: D-019 or
LMF48-SC and VFGT36 inch models:
D-027). See Figures 28, 28A, 28B, and
28C for reference. The log has a rectan-
gular shape on the bottom that fits against
the lip on the black metal base, the square
grate, and the round tube burner. Slide the
log in place as shown in Figures.
Figure 28 - Installing Right Front Log
Figure 28A - Installing Right Front Log,
Top View
Burner
Tube
Grate Finger
Right Front Log
(D061, D-019 or D027)
Round Tube
Burner
Grate Finger
Figure 28B - Installing Right Front Log,
Top View
Burner Tube
Square Grate
Burner System Model
Refractory Concrete
Logs For Use With This
Burner System
MF42INE,MF42IPE,
LMF36-SC
LMF42-SC
MF48INE, MF48IPE,
LMF48-SC