FMI Masonry MM39 Скачать руководство пользователя страница 2

Fireplace Parts Diagram .........................................................................................Pg. 2
Fireplace Parts List .................................................................................................Pg. 3
General Information ................................................................................................Pg. 4
Safety Information ...................................................................................................Pg. 5
Location ...................................................................................................................Pg. 6
Supporting Floor Systems .......................................................................................Pg. 6 ~ 7
Grand Meridian Weight Determinations ..................................................................Pg. 8
Clearances ..............................................................................................................Pg. 9,10
Air for Combustion and Ventilation ..........................................................................Pg. 10,11
Important Pre-installation Information .....................................................................Pg. 12
Fireplace Assembly Procedures ..............................................................................Pg. 13 ~ 15
Gas Piping Installation ............................................................................................Pg. 15
Electrical Line Feed .................................................................................................Pg. 15
Firebrick Liner Installation .......................................................................................Pg. 16
Initial Fireplace Operation .......................................................................................Pg. 16
Technical Service ....................................................................................................Pg. 16
Replacement Parts ..................................................................................................Pg. 16
Appendix I ...............................................................................................................Pg. 17
Appendix II ..............................................................................................................Pg. 18
Warranty Information ...............................................................................................Pg. 19

CONTENTS

2.625”

6.500”

.125”

.125”

Refer to installation instructions and check local codes prior to installing. This appliance must be installed in accordance 

with local codes if any. Otherwise, in accordance with the National Fuel Gas Code ANSI Z223.1 installation codes.

P/N MFP170  OCT2009

COMPLIES WITH ANSI Z21.91-2007, VENTLESS FIREBOX ENCLOSURES FOR GAS-FIRED UNVENTED DECORATIVE ROOM 

HEATERS. FOR USE WITH LISTED ANSI Z21.11.2 UNVENTED DECORATIVE ROOM HEATERS, NOT TO EXCEED 40,000 BTU/HR. 

0" - 10" : NO PROJECTIONS

10" - 16" : 1½" MAX. PROJ.

16" - 22" : MAX. PROJ.

22" & ABOVE : 10" MAX. PROJ.

DISTANCE FROM SIDE OPENINGS

3" MIN. : 1¾" MAX. PROJ.

MANTEL CLEARANCES

2701 S. Harbor Blvd.

Santa Ana, CA 92704

THIS APPLIANCE NEEDS 

FRESH AIR FOR SAFE 

OPERATION AND MUST 

BE INSTALLED SO 

THERE ARE PROVISIONS 

FOR ADEQUATE 

COMBUSTION AND 

VENTILATION AIR.

DO NOT REMOVE THIS LABEL

MODEL No.:

MM44VF

MM49VF

MM39VF

SERIAL No.

DATE OF MFG:

BOTTOM 0"

2"

42"

18½"

TOP, 

BACK & 

SIDES

OPENING 

TO CEILING

CLEARANCES TO COMBUSTIBLES

RECESS 

DEPTH

PFS

®

US

7. HOLES: 4X Ø.125” THRU

6. CLEAR BOXES NEXT TO MODEL NUMBERS ARE TO BE STAMPED DURING MANUFACTURE OF FIREPLACE.

5. LARGE TEXT TO BOLD UPPERCASE ARIAL, 10 PT. MIN. (WHERE SHOWN).

4. SMALLEST TEXT TO BE ARIAL, 8 PT. MIN (WHERE SHOWN).

3. ALL TEXT AND GRAPHICS TO BE BLACK ON A CONTRASTING, CLEAR ALUMINUM BACKGROUND.

2. FINISH: CLEAR MYLAR TO BE APPLIED ON TOP SURFACE.

1. MATERIAL:  CLASS IIIA , .024 THICK ALUMINUM RATED AT 302°F (150°C).

NOTES

: UNLESS OTHERWISE SPECIFIED

DESCRIPTION:   PLATE, RATING VF

PART NUMBER: 125122-01

REV: A

DATE: 11/3/2009

LAST MODIFIED BY: CHRISTI

Doc File Name: 125122-01.ai

Below is a sample picture of the rating plate that is located inside the lower dome side of your fireplace. Model Number, Date of 

Manufacture and Serial Number should be stamped on the plate where indicated.

Содержание Masonry MM39

Страница 1: ...and approved by PFS under ANSI Z21 91 for use with any ANSI Z21 11 2 approved gas logs FORUSEONLYWITHALISTEDGAS FIREDUNVENTED DECORATIVE ROOM HEATER NOT TO EXCEED 40 000 BTU HR DO NOT BUILD A WOOD FI...

Страница 2: ...WITH ANSI Z21 91 2007 VENTLESS FIREBOX ENCLOSURES FOR GAS FIRED UNVENTED DECORATIVE ROOM HEATERS FOR USE WITH LISTED ANSI Z21 11 2 UNVENTED DECORATIVE ROOM HEATERS NOT TO EXCEED 40 000 BTU HR 0 10 NO...

Страница 3: ...d Diagram 5 9 12 2 7 1 3A 2X 2X 3X 7X 2X 8X 3 6 11 Warning Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may re...

Страница 4: ...ireplace Parts List ITEM P N DESCRIPTION QTY 1 MFP39 1 MFP44 1 MFP49 1 HEARTH Left or Right 2 2 MFP39 2 MFP44 2 MFP49 2 REAR WALL 4 3 MFP39 3 MFP44 3 MFP49 3 SIDE WALL 7 3A MFP39 3A MFP44 3A MFP49 3A...

Страница 5: ...erve as a primary heat source rather the fireplace was expressly created as a supplemental source of heat The Grand Meridian Fireplace is Designed for Use Only with any Vent free decorative gas log se...

Страница 6: ...ace if not enough fresh air is available See Air for Combustion and Ventilation page 8 If the fireplace keeps shutting off see appliance manufacturers troubleshooting instructions 9 Do not run firepla...

Страница 7: ...ian fireplace Check with the local jurisdiction before you get started Supporting Floor Systems Floor Framing It is important to take into consideration that the load for the Grand Meridian Fireplace...

Страница 8: ...dian Fireplace must be considered as additional dead load that will have to be supported by the floor framing Additional floor joists or I joists may be required as determined by the licensed design p...

Страница 9: ...d structural members having a moisture content of less than 16 per cent at time of installation and used under dry conditions the deflection resulting from L 0 5D is permitted to be substituted for th...

Страница 10: ...designed to be custom finished with facing trim and mantle to be an owner option However all such trim material must meet standard fireplace code requirements Non combustible facing material must be...

Страница 11: ...he house to operate You must provide adequate fresh air for these appliances This will insure proper venting of vented fuel burning appliances Non combustible Flex Hose Figure 16 Exterior Providing Ad...

Страница 12: ..._ Btu hr Total _ _______ Btu hr Example Gas water heater 40 000 Btu hr Vent free fireplace 36 000 Btu hr Total 76 000 Btu hr Do not include direct vented gas appliances Direct vent draws combustion ai...

Страница 13: ...prior to assembly This will minimize shrinkage and cracks developing in the joint areas Best way to accomplish this is with a bucket of water and a large sponge Dip sponge into water and apply a liber...

Страница 14: ...28 Apply mortar between joints 12 inch rebar Mix a batch of mortar and prepare Right Side Hearth bottom 2 surface to be bonded as shown in Figure 18 Figure 18 1 2 AWAY FROM EDGES 1 2 MORTAR BEAD TYPIC...

Страница 15: ...rebar to all 8 cells as shown in Figure 22 The rebar should enter the holes in the Hearth and lie adjacent to the 12 rebar secured in subfloor Then fill cells with approx 2 cu ft Ready Mix Concrete F...

Страница 16: ...Fuel Gas Code ANSI Z223 1 This gas pipe provision must only be connected to an approved vent free gas log heater certified to ANSI Z21 11 2 heater standard Check local building codes for specific pip...

Страница 17: ...smells created from the heater and fireplace curing We suggest operating the heater for several 30 minute intervals allowing the fireplace to cool for an hour in between This will allow any moisture i...

Страница 18: ...ncrete slab The concrete strength and durability shall comply with Sections 1903 1904 and 1905 of the International Building Code IBC TABLE R402 2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE MI...

Страница 19: ...ly b Lines defining areas are approximate only Local conditions may be more or less severe than indicated by region classification A severe classification is where weather conditions result in signifi...

Страница 20: ...components FMI PRODUCTS LLC is not responsible for misuse or mishandling of component parts Nothing in this warranty makes FMI PRODUCTS LLC or any entity thereof liable in any respect for any injury...