www.fmiproducts.com
124702-01E
23
SPECIFICATIONS
HD18PRB
• Rating: 25,000/36,000 Btu/hr
• Gas Type: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 8.0" w.c.
• Inlet Supply Pressure (inches of water):
Maximum - 14" w.c., Minimum - 11" w.c.
HD24PRB
• Rating: 25,000/36,000 Btu/hr
• Gas Type: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 8.0" w.c.
• Inlet Supply Pressure (inches of water):
Maximum - 14" w.c., Minimum - 11" w.c.
HD18NRB
• Rating: 25,000/36,000 Btu/hr
• Gas Type: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" w.c.
• Inlet Supply Pressure (inches of water):
Maximum - 10.5" w.c., Minimum - 5" w.c.
HD24NRB
• Rating: 25,000/36,000 Btu/hr
• Gas Type: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" w.c.
• Inlet Supply Pressure (inches of water):
Maximum - 10.5" w.c., Minimum - 5" w.c.
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• for propane/LP units, propane/LP gas sup
-
ply may be low
You may feel your gas pressure is too low. If
so, contact your local propane/LP or natural
gas supplier.
TECHNICAL SERVICE
You may have further questions about instal
-
lation, operation or troubleshooting. If so, con
-
tact FMI PRODUCTS, LLC at 1-866-328-4537.
When calling please have your model and
serial numbers of your heater ready.
You can also visit our web site at
www.fmiproducts.com.