www.fmiproducts.com
124702-01E
17
INSTALLATION
Continued
PRESSURE TESTING HEATER GAS
CONNECTIONS
1. Open equipment shutoff valve (see
Figure 17, page 16).
2. Open main gas valve located on or near
gas meter for natural gas or open pro-
pane/LP supply tank valve.
3. Make sure control knob of heater is in the
OFF position.
4. Check all joints from equipment shutoff
valve to gas control (see Figures 16 and
17, page 16). Apply noncorrosive leak
detection fluid to all joints. Bubbles form
-
ing show a leak.
5. Correct all leaks at once.
6. Light heater (see
Operation
, page 18).
Check all other internal joints for leaks.
7. Turn off heater (see
To Turn Off Gas to
Appliance
, page 20).
INSTALLING LOGS
WARNING: Failure to position
the parts in accordance with these
diagrams or failure to use only
parts specifically approved with
this heater may result in property
damage or personal injury.
CAUTION: After installa-
tion and periodically thereafter,
check to ensure that no flame
comes in contact with any log.
With the heater set to HI, check
to see if flames contact any log. If
so, reposition logs according to
the log installation instructions
in this manual. Flames contact
-
ing logs will create soot.
It is very important to install these logs exactly
as instructed. Do not modify logs. Only use
logs supplied with heater.
1. Place rear log onto base. Holes in bottom
of log must seat over pins on base as
shown in Figure 18.
2. Place center log onto base. Holes in bot-
tom of log must seat over pins on base
as shown in Figure 18.
3. Place front log onto grate as shown in
Figure 19. Front log has cut outs for the
fingers of the grate to fit into.
4. Place left crossover log as shown in Fig
-
ure 20, page 18. Match square peg on top
of center log with square hole on bottom
of left crossover log. Match pin on top of
front log with round hole on bottom of left
crossover log.
Figure 18 - Installing Rear and Middle
Logs
Rear Log
Burner
Pin for
Hole in
Bottom
of Log
Center Log
Figure 19 - Installing Front Log
Front Log
Grate