www.fmiproducts.com
124531-01C
15
INSTALLATION
Continued
Figure 14 - Equipment Shutoff Valve
Equipment Shutoff Valve
Propane/LP
Supply Tank
Control Valve
Location
Figure 15 - Checking Gas Joints
(Propane/LP Gas Only)
Open
Closed
Equipment
Shutoff Valve
35(6685(7(67,1**$66833/<
3,3,1*6<67(0
7HVW3UHVVXUHV,Q([FHVV2I36,*
N3D
'LVFRQQHFW DSSOLDQFH ZLWK LWV DSSOLDQFH
main gas valve (control valve) and equip-
ment shutoff valve from gas supply piping.
3UHVVXUHVLQH[FHVVRISVLJZLOOGDP
-
age heater regulator.
&DSRIIRSHQHQGRIJDVSLSHZKHUHHTXLS
-
PHQWVKXWRIIYDOYHZDVFRQQHFWHG
3UHVVXUL]HVXSSO\SLSLQJV\VWHPE\HLWKHU
opening propane/LP supply tank valve
for propane/LP gas or opening main gas
valve located on or near gas meter for
natural gas or using compressed air.
4. Check all joints of gas supply piping sys-
tem. Apply a commercial leak detection
VROXWLRQWRDOOMRLQWV%XEEOHVIRUPLQJVKRZ
a leak.
5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff
valve to gas supply. Check reconnected
¿WWLQJVIRUOHDNV
7HVW3UHVVXUHV(TXDO7RRU/HVV7KDQ
36,*N3D
1. Close equipment shutoff valve (see Fig-
ure 14).
3UHVVXUL]HVXSSO\SLSLQJV\VWHPE\HLWKHU
opening propane/LP supply tank valve
for propane/LP gas or opening main gas
valve located on or near gas meter for
natural gas or using compressed air.
3. Check all joints from gas meter (natural
gas) or propane/LP supply to equipment
shutoff valve (see Figure 15 or 16). Apply
a commercial leak detection solution to all
MRLQWV%XEEOHVIRUPLQJVKRZDOHDN
4. Correct all leaks at once.
35(6685(7(67,1*+($7(5*$6
CONNECTIONS
1. Open equipment shutoff valve (see Fig-
ure 14).
2. Open main gas valve located on or near
gas meter for natural gas or open pro-
pane/LP supply tank valve.
3. Make sure control knob of heater is in the
OFF position.
Figure 16 - Checking Gas Joints
(Natural Gas Only)
Gas
Meter
Equipment Shutoff Valve
Control Valve Location
4. Check all joints from gas meter (natural
gas) or propane/LP supply to equipment
shutoff valve (see Figure 15 or 16). Apply
a commercial leak detection solution to all
MRLQWV%XEEOHVIRUPLQJVKRZDOHDN
5. Correct all leaks at once.
6. Light heater (see
Operation
SDJH
Check all other internal joints for leaks.
7. Turn off heater (see
To Turn Off Gas to
Appliance
SDJH